4.2 FT82 SERVOPACK with MECHATROLINK-II Communications References
4
Parameter Li
s
t
s
4-55
Pn601
2
Dynamic Brake Resis-
tor Allowable Energy
Consumption
0 to 65,535
10 J
0
All
After
restart
Setup
*7
Pn603
2
Regenerative Resis-
tance
0 to 65,535
10 m
Ω
0
All
Immedi-
ately
Setup
*1
Pn604
2
Dynamic Brake Resis-
tance
0 to 65,535
10 m
Ω
0
All
After
restart
Setup
*7
Pn61A
2
Overheat Protection
Selections
0000h to
0003h
–
0000h
Linear
After
restart
Setup
*1
Pn61B
*9
2
Overheat Alarm Level
0 to 500
0.01 V
250
All
Immedi-
ately
Setup
*1
Pn61C
*9
2
Overheat Warning Level
0 to 100
1%
100
All
Immedi-
ately
Setup
*1
Pn61D
*9
2
Overheat Alarm Filter
Time
0 to 65,535
1 s
0
All
Immedi-
ately
Setup
*1
Pn621 to
Pn628
*4
–
Safety Module-Related
Parameters
–
–
–
All
–
–
–
Pn800
2
Communications Con-
trols
0000h to
0F73h
–
0040h
All
Immedi-
ately
Setup
*2
Continued on next page.
Continued from previous page.
Parameter
No.
Siz
e
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.
X
Overheat Protection Selection
0
Disable overheat protection.
1
Use overheat protection in the Yaskawa Linear Servomotor.
*8
2
Monitor a negative voltage input from a sensor attached to the machine and
use overheat protection.
3
Monitor a positive voltage input from a sensor attached to the machine and
use overheat protection.
n.
X
Reserved parameter (Do not change.)
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
n.
X
MECHATROLINK Communications Check Mask for Debugging
0
Do not mask.
1
Ignore MECHATROLINK communications errors (A.E60).
2
Ignore WDT errors (A.E50).
3
Ignore both MECHATROLINK communications errors (A.E60) and WDT
errors (A.E50).
n.
X
Warning Check Masks
0
Do not mask.
1
Ignore data setting warnings (A.94
).
2
Ignore command warnings (A.95
).
3
Ignore both A.94
and A.95
warnings.
4
Ignore communications warnings (A.96
).
5
Ignore both A.94
and A.96
warnings.
6
Ignore both A.95
and A.96
warnings.
7
Ignore A.94
, A.95
, and A.96
warnings.
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)