3.5 FT83 SERVOPACKs with Analog Voltage/Pulse Train References
3.5.4 INDEXER Alarm Displays and Troubleshooting
3-234
3.5.4
INDEXER Alarm Displays and Troubleshooting
INDEXER alarms and corrections for them are given in the following table.
Error
Number
Alarm
Number
Alarm Name
Meaning
Corrective Action
Servo-
motor
Stop
Method
Alarm
Reset
E12A
A.EF9
System Alarm
The firmware pro-
cessing time was
too long.
•
Upgrade the firm-
ware version.
•
Reduce the number
of functions being
used.
Gr.1
N/A
E13A
A.EF9
Firmware
Version
Unmatched
The SERVOPACK
does not support
this function,
because the soft-
ware version do not
match.
•
Upgrade the SER-
VOPACK software
version.
•
Use the SERVO-
PACK that supports
the corresponding
function.
•
Use the SERVO-
PACK with the func-
tion set disabled.
Gr.1
N/A
E14A
A.EF9
Parameter
Checksum
Alarm
(Detected only
when control
power supply is
turned ON.)
Incorrect or cor-
rupted parameters
are stored in
EEPROM.
(This alarm can
occur if the control
power supply is
turned OFF while the
parameters are
being initialized or
changed.)
•
Initialize the param-
eters. (Fn005)
•
If the problem is not
solved, correct the
parameters.
Gr.1
N/A
E15A
A.EF9
Parameter
Version
Unmatched
(Detected only
when the control
power supply is
turned ON.)
The combination of
the firmware version
number and the
parameter version
number is wrong.
•
Change the firm-
ware version.
•
Change the param-
eter version to
match the firmware
version.
Gr.1
N/A
E16A
A.EF9
Parameter Out-
of-range Alarm
(Detected only
when control
power supply is
turned ON.)
The origin position
(Pn63C) exceeded
the position range
(Pn638 and Pn63A)
for rotational coordi-
nates (Pn637 not set
to n.
0).
Correct the origin set-
ting (Pn63C) or the
position range (Pn638
and Pn63A).
Gr.1
N/A
Continued on next page.