125
Reference Manual
Graphic EQ, Parametric EQ, Effects, and PREMIUM RACK
Virtual rack operations
This section explains how to mount a GEQ, PEQ, or effect in the virtual rack, and patch the
input and output of the rack as an example.
STEP
1.
In the Function Access Area, press the RACK button.
2.
In the upper part of the VIRTUAL RACK window, press the GEQ 1-8, GEQ 9-16, or
EFFECT tab.
3.
To mount a GEQ, PEQ, or effect in the rack, press the rack mount button for that
rack.
4.
Use the buttons in the MODULE SELECT field in the RACK MOUNTER window to
select the item you want to mount, and press the OK button.
5.
Press the INPUT PATCH button.
6.
In the CH SELECT window, select the input source and then press the OK button.
7.
Press the OUTPUT PATCH button.
8.
In the CH SELECT window, select the output destination and then press the OK
button.
VIRTUAL RACK screen
1
Rack tabs
Selects the type of rack you want to display on the screen. Choose from GEQ 1-8, GEQ
9-16 (GEQ rack), EFFECT (effect rack), or PREMIUM (Premium Rack).
2
Rack mount button
Press this button to open the RACK MOUNTER window, in which you can select the type
of the rack you want to mount.
Function
Access Area
NOTE
VIRTUAL RACK window
3
SAFE button
Switches Recall Safe on or off for the rack. If this button is turned on for a rack, the
contents and parameters of that rack will not change when a scene is recalled. For more
information on Recall Safe, refer to “
Using the Recall Safe function
The Recall Safe settings of each rack will not preserve the input/output patching to that
• In steps 6 and 8, you can make settings such that the confirmation dialog box will not appear
• The type of GEQ, PEQ, or effect mounted in each rack, its parameter settings, and the input-
source and output-destination settings are saved as part of the scene.
rack. Recall Safe settings for patching must be made on the input-source or output-
destination channel.
1
2 3 4
6
5
1
2 3 4
6
5
USO
RESTRITO
Содержание CL5