MIDI
171
Reference Manual
MIDI/GPI screen (CONTROL CHANGE page)
You can specify how Control Changes will be transmitted and received, and specify the event
(fader/knob operation, [ON] key on/off operation, etc.) assigned to each control number.
NOTE
The channel on which Control Changes are transmitted and received is specified by the PORT/
CH field on the MIDI SETUP page (
3
List
Shows the event (fader/knob operation, [ON] key on/off operation, etc.) assigned to
each control number.
1
2
•
NO.
.........................This indicates the control number. You can use control numbers 1-
31, 33-95, and 102-119.
• CONTROL CHANGE EVENT
.........................Indicates and enables you to select the type of event assigned to
each control number. When you press an event, the MIDI
CONTROL CHANGE window will appear, allowing you to change
the control number assignment.
3
4
CLEAR ALL button
Press this button to clear all event assignments on the list.
5
INITIALIZE ALL button
Press this button to restore all event assignments on the list to their default state.
4
6
Scroll knob
6
5
Scrolls the contents of the list. You can use the multifunction knobs to operate this.
1
CONTROL CHANGE field
Enables you to switch Control Change transmission/reception on or off, and specify
whether Control Changes will be echoed out. This setting is linked with the CONTROL
CHANGE field on the MIDI SETUP page.
•
Tx button
............................... Switches control change transmission on/off.
•
Rx button
............................... Switches control change reception on/off.
•
ECHO button
......................... Selects whether incoming control changes will be
echoed out from the MIDI transmit port.
2
CONTROL CHANGE MODE field
This field enables you to select the Control Change transmission/reception mode. This
setting is linked with the CONTROL CHANGE MODE field on the MIDI SETUP page.
•
NRPN mode (when the NRPN button is on):
Various mix parameters on the CL series console will be transmitted and received on a
single MIDI channel as NRPN messages. If you select this mode, the assignments in the
list will be ignored.
•
TABLE mode (when the TABLE button is on):
Various mix parameters on the CL series console will be transmitted and received on a
single MIDI channel as Control Change messages, according to the assignments in the
list.