Setup
240
Reference Manual
3
GPI OUT SETUP button
The button shows the name of the currently-selected function or parameter. Press this
button to display the GPI OUT SETUP window.
You can assign the following functions.
Using FADER START
Make FADER START settings if you want a device connected to a GPI OUT port to operate
in tandem with fader operations.
STEP
1.
Connect an external device to the CL series console's GPI connector.
2.
In the Function Access Area, press the SETUP button.
3.
In the SETUP screen, press the MIDI/GPI button.
4.
In the MIDI/GPI screen, press the FADER START tab.
5.
For each GPI OUT port, specify the channel that will cause the external device to
operate, and the type of operation.
SETUP screen
MIDI/GPI screen
4
TEST button
While this is on, the corresponding GPI OUT port will be active and will output a control
signal.
Function
PARAMETER 1
PARAMETER 2
Description
NO ASSIGN
-
-
No assignment
CUE ACTIVE
CUE ON
-
Turn on the [CUE] key of the
selected channel
DCA ONLY
-
Turn on the DCA [CUE] key
INPUT ONLY
-
Turn on the [CUE] key of an input
channel
OUTPUT ONLY
-
Turn on the [CUE] key of an output
channel
DANTE
REDUNDANCY
IND.
PRIMARY
This function activates when the
unit is operating on the primary
Dante audio network with a star
connection (redundancy network).
SECONDARY
This function activates when the
unit is operating on the secondary
Dante audio network with a star
connection (redundancy network).
GPI IN ACTIVE
IND.
SPECIFIC PORT PORT 1 to PORT 5
The function assigned to GPI IN
port 1 - 5 becomes active
POWER ON
-
-
The power of the CL series
console is turned on
USER DEF.
KEY ACTIVE
IND.
SPECIFIC
NUMBER
USER DEFINED
KEY 1 to USER
DEFINED KEY 16
The function assigned to the
USER DEFINED key becomes
active