Valves
The valves in the LP SCR system are used for the different operation modes. The LP SCR
system has the valves that follow:
○
V1 - reactor inlet valve
○
V2 - reactor outlet valve
○
V3 - reactor bypass valve
○
V4 - turbine bypass valve
The turbine bypass valve (V4) is also used for other functions of the ECS, for example for
low-load tuning (LLT) or for steam production control (SPC).
4.12.1.2
Layout
The LP SCR system can be designed in different layouts related to the project. Two examples are
shown in
and
.
Fig 4-13
LP SCR temperature controlled (example)
V3
V1
V4
V2
003
004
005
001
006
002
Legend
001
Engine
004
Burner
002
Urea dosing unit
005
LP SCR reactor
003
Decomposition unit
006
Turbocharger
X92-B
AA00-9270-00AAA-043B-A
Operation Manual
LP Selective catalytic reduction system
Winterthur Gas & Diesel Ltd.
- 93 -
Issue 002 2021-11