PROCEDURE
1
In the control room (control console), or on the local control panel, push the EMERGENCY
STOP button.
NOTE:
The ECS stops the engine immediately.
2
For a DF engine, start the exhaust ventilation sequence, if there is a ventilation request.
3
To make the engine ready for restart after an emergency stop, you must reset the
EMERGENCY STOP button.
CAUTION
Damage Hazard. Do this step only as a last alternative selection, if the EMERGENCY STOP
button is not working. Damage to the engine can occur.
4
In the power supply boxes E85.1 to E85.#, set to OFF the electrical power to the ECS.
5
Find the cause of the emergency stop and repair the fault.
CLOSE UP
•
None
X92-B
AA00-0000-00AAA-141A-A
Operation Manual
Emergency stop the engine
Winterthur Gas & Diesel Ltd.
- 289 -