Table 5-2 - iELBA - error indication
shows the possible iELBA error indications related to the
number of flashes of the indicator light.
NOTE:
The error indications are active in automatic mode and in manual mode.
Tab 5-2
iELBA - error indication
Number of
flashes
Status
iELBA state
1
Start OK, “Boost to Control Speed Threshold” not OK
OFF
2
Start OK, “Setpoint Speed” not OK in 60 s
OFF
3
Start OK, speed OK, “Phase Synchronisation” not OK in 60 s
OFF
4
Overspeed error
OFF
5
Electric motor error
OFF
6
The lubricating oil pressure is too low
OFF
7
iELBA pickup sensor error
OFF
8
TDC pickup sensor error
Usual operation
9
BDC pickup sensor error
Usual operation
X92-B
AA00-7752-00AAA-043A-A
Operation Manual
Integrated electrical balancer (iELBA)
Winterthur Gas & Diesel Ltd.
- 195 -