2.5
Prevent explosions in the crankcase
Periodicity
Description
Unscheduled
Duration for performing preliminary requirements
0.0 man-hours
Duration for performing the procedure
1.0 man-hours
Duration for performing the requirements after job completion
0.0 man-hours
Personnel
Description
Specialization
QTY
Engine crew
Basic
1
Support equipment
Description
Part No.
CSN
QTY
None
Supplies
Description
QTY
None
Spare Parts
Description
Part No.
CSN
QTY
None
SAFETY PRECAUTIONS
WARNING
Danger: If an oil mist alarm is activated, keep away from the engine. There is a risk of
explosion.
WARNING
Danger: Do not open the crankcase doors or the covers for a minimum of 20 minutes after
engine stop. If air goes into the crankcase, an explosion can occur.
WARNING
Injury hazard: The crankcase doors have relief valves. To prevent accidents no person must
be in the areas of gases that can come out of these relief valves. Injury to personnel can
occur.
PRELIMINARY OPERATIONS
•
None
X92-B
AA00-0000-00AAA-012D-A
Operation Manual
Prevent explosions in the crankcase
Winterthur Gas & Diesel Ltd.
- 52 -
Issue 002 2021-11
Содержание X92-B
Страница 8: ...X92 B Operation Manual Page left intentionally blank Winterthur Gas Diesel Ltd 8 Issue 002 2021 11...
Страница 12: ...X92 B Operation Manual Page left intentionally blank Winterthur Gas Diesel Ltd 12 Issue 002 2021 11...
Страница 113: ...X92 B Operation Manual Page left intentionally blank Winterthur Gas Diesel Ltd 113 Issue 002 2021 11...
Страница 241: ...7 Installation 7 1 Installation 242 X92 B Operation Manual Winterthur Gas Diesel Ltd 241 Issue 002 2021 11...