Problem
Probable Causes
Corrective Action
Frypots won’t top off.
A.
Empty JIB.
B.
Probe temperature lower than setpoint.
C.
Oil is too cold.
D.
Crumb build up around sensor.
E.
Bad Connection
F.
ATO board power loss
G.
Failed transformer/harness.
H.
ATO pump failed.
I.
Failed ATO board.
J.
ATO lines/pump plugged
A.
Ensure JIB has oil.
B.
Check to see that fryer is heating. Fryer
temperature must be at setpoint. Check
probe resistance. If probe is bad, replace
the probe.
C.
Ensure that the oil in the JIB is above
70°F (21°C).
D.
Clean crumbs from opening surrounding
sensor.
E.
With the controller OFF, press the
temperature button and ensure the ATO
software version appears. If not, the
connection between the AIF and the ATO
board may be bad. Ensure the 6-pin CAN
connectors are tight between AIF (J4 and
J5) and ATO (J9 or J10) boards.
F.
Power to the ATO board has been cut off.
Restore power to the board and clear any
service required errors.
G.
Ensure transformer in ATO box is
functioning properly. Check power from
transformer to ATO board. Ensure all
harnesses are plugged securely into place.
H.
Ensure pump is operational. Check
voltage to pump. Replace the pump if
defective.
I.
Check for proper voltages using the pin
position chart found on page 1-28. If
ATO found defective, replace ATO
board.
J.
Clear the lines/pump.
Incorrect vat tops off.
A.
Wired incorrectly.
B.
Flexlines connected to wrong vat.
A.
Check wiring.
B.
Switch flexlines to correct vat.
One vat doesn’t top off.
A.
Filter error exists.
B.
Actuator, pump, loose connection, RTD
or ATO issue.
A.
Clear filter error properly. When
CHANGE FILTER PAPER YES/NO is
displayed, do NOT press any button until
the pan has been removed for at least
thirty seconds. After thirty seconds the
controller returns to OFF or last display.
B.
Check actuator, ATO pump, ATO board,
wire connections and RTD.
Controller displays
SERVICE
REQUIRED
–
ATO
BOARD
A.
Loose or bad fuse
B.
Bad Connection
C.
ATO Board power loss
A.
Ensure fuse on right side of ATO box is
secure and good.
B.
With the controller OFF, press the
temperature button and ensure the ATO
software version appears. If not, the
connection between the AIF and the ATO
board may be bad. Ensure the 6-pin CAN
connectors are tight between AIF (J4 and
J5) and ATO (J9 or J10) boards.
C.
Power to the ATO board has been cut off.
Ensure there is correct voltage to the
ATO transformer. Restore power to the
board and clear any service required
errors.
Содержание Frymaster FilterQuick 2FQG30U
Страница 8: ...1 3 ...
Страница 41: ...1 36 1 16 2 Bulk Wiring ...
Страница 56: ...1 51 1 18 6 Clogged Drain Failed Oil Sensor Error Flowchart ...
Страница 57: ...1 52 1 18 7 Menu Trees 1 18 7 1 FilterQuick Controller Setup Menu Tree ...
Страница 58: ...1 53 1 18 7 2 FilterQuick Filter and Info Mode Menu Tree ...
Страница 62: ...1 57 1 20 Principal Wiring Connections ...
Страница 63: ...1 58 1 21 Wiring Diagrams 1 21 1 Main FQG 230 430 120V CE Export ...
Страница 64: ...1 59 1 21 2 Main FQG 230 430 Australia ...
Страница 65: ...1 60 1 21 3 Main FQG 230 430 120V CE Export with Solid Shortening ...
Страница 66: ...1 61 1 21 4 Main FQG 230 430 Australia with Solid Shortening ...
Страница 67: ...1 62 1 21 5 Main FQG 330 530 120V CE Export ...
Страница 68: ...1 63 1 21 6 Main FQG 330 530 Australia ...
Страница 69: ...1 64 1 21 7 Main FQG 330 530 120V CE Export with Solid Shortening ...
Страница 70: ...1 65 1 21 8 Main FQG 330 530 Australia with Solid Shortening ...
Страница 71: ...1 66 1 21 9 Transformer Filter Box 430 530 ...
Страница 72: ...1 67 1 22 Simplified Wiring Diagrams 1 22 1 FilterQuick FQG30 Series Simplified Wiring with Push Pull Handles ...
Страница 73: ...1 68 1 22 2 FilterQuick FQG30 Series Simplified Wiring with Push Buttons ...
Страница 74: ...1 69 1 22 3 FilterQuick FQG30 Series Data Network Flowchart ...
Страница 76: ...1 71 1 24 Shortening Melting Unit Wiring Diagram ...
Страница 77: ...1 72 1 25 Modular Basket Lift Wiring Diagram 100 120V 1 2 4 3 5 6 12 7 8050518E ...
Страница 79: ...1 74 1 27 Basket Lift Interface Harness ...