1-40
Problem
Probable Causes
Corrective Action
Actuator doesn’t
function cont.
C.
AIF board failure.
D.
Actuator readings are out of tolerance.
E.
Actuator defective.
C.
Check power on the connector of the
problem actuator while trying to
manually open or close an actuator.
Pins 1 (Black) and 4 (White) should
read +24VDC when the actuator is
opening. Pins 2 (Red) and 4 (White)
should measure -24VDC when the
actuator is closing). If either voltage is
missing, the AIF board is likely bad.
Test the actuator by plugging into
another connector. If the actuator
operates, replace the board.
D.
Check resistance of the potentiometer
between pin 3 (blue wire) and pin 4
(gray/white wire). Closed should read
0-560
Ω
. Open should read 3.8K
Ω
–
6.6K
Ω
.
E.
If proper voltages are present at the
connector and actuator doesn’t operate
reset power to the fryer, if it still
doesn’t operate replace the actuator.
Actuator functions on
wrong vat.
A.
Actuator plugged into wrong connector.
B.
Locator pin is in wrong position.
A.
Ensure the actuator is plugged into
correct connection (J1 for FV return,
J3 for DV return and J6 for FV drain
and J7 for DV drain).
B.
Ensure the locator pin is in proper
position in plug J2. See table B on
page 1-65.
Содержание Frymaster FilterQuick 2FQG30U
Страница 8: ...1 3 ...
Страница 41: ...1 36 1 16 2 Bulk Wiring ...
Страница 56: ...1 51 1 18 6 Clogged Drain Failed Oil Sensor Error Flowchart ...
Страница 57: ...1 52 1 18 7 Menu Trees 1 18 7 1 FilterQuick Controller Setup Menu Tree ...
Страница 58: ...1 53 1 18 7 2 FilterQuick Filter and Info Mode Menu Tree ...
Страница 62: ...1 57 1 20 Principal Wiring Connections ...
Страница 63: ...1 58 1 21 Wiring Diagrams 1 21 1 Main FQG 230 430 120V CE Export ...
Страница 64: ...1 59 1 21 2 Main FQG 230 430 Australia ...
Страница 65: ...1 60 1 21 3 Main FQG 230 430 120V CE Export with Solid Shortening ...
Страница 66: ...1 61 1 21 4 Main FQG 230 430 Australia with Solid Shortening ...
Страница 67: ...1 62 1 21 5 Main FQG 330 530 120V CE Export ...
Страница 68: ...1 63 1 21 6 Main FQG 330 530 Australia ...
Страница 69: ...1 64 1 21 7 Main FQG 330 530 120V CE Export with Solid Shortening ...
Страница 70: ...1 65 1 21 8 Main FQG 330 530 Australia with Solid Shortening ...
Страница 71: ...1 66 1 21 9 Transformer Filter Box 430 530 ...
Страница 72: ...1 67 1 22 Simplified Wiring Diagrams 1 22 1 FilterQuick FQG30 Series Simplified Wiring with Push Pull Handles ...
Страница 73: ...1 68 1 22 2 FilterQuick FQG30 Series Simplified Wiring with Push Buttons ...
Страница 74: ...1 69 1 22 3 FilterQuick FQG30 Series Data Network Flowchart ...
Страница 76: ...1 71 1 24 Shortening Melting Unit Wiring Diagram ...
Страница 77: ...1 72 1 25 Modular Basket Lift Wiring Diagram 100 120V 1 2 4 3 5 6 12 7 8050518E ...
Страница 79: ...1 74 1 27 Basket Lift Interface Harness ...