1-49
CODE
ERROR MESSAGE
EXPLANATION
E13
ERROR RETURN VALVE NOT CLOSED
Return valve failed to close; the valve’s position is
unknown.
E14
ERROR AIF BOARD
MIB detects AIF missing; AIF board failure
E15
ERROR MIB BOARD
Cooking controller detects MIB connections lost;
Check software version on each controller. If
versions are missing, check CAN connections
between each controller; MIB board failure
E16
ERROR AIF PROBE
AIF RTD reading out of range
E17
ERROR ATO PROBE
ATO RTD reading out of range
E19
CAN TX FULL
Connection between controllers lost
E20
INVALID CODE LOCATION
SD card removed during update
E21
FILTER PAPER PROCEDURE ERROR
(Change Filter Paper)
25 hour timer has expired or dirty filter logic has
activated
E22
OIL IN PAN ERROR
The MIB has reset the oil in pan flag.
E23
CLOGGED DRAIN (Gas)
Vat did not empty during filtration
E24
OIL SENSOR FAILED (Gas)
Oil is back sensor failed.
E25
RECOVERY FAULT
Recovery time exceeded maximum time limit.
E27
LOW TEMP ALARM
Oil is approximately 35°F (19.4°C) below setpoint.
E28
HIGH TEMP ALARM
Oil temperature has risen 40°F (22.2°C) higher than
setpoint. If temperature continues to rise, the high
limit will shut the burner off when temperature
reaches 425°F (218°C) Non-CE or 395°F (202°C) CE.
E70
OQS TEMP HIGH
Oil temperature is too high for a valid OQS reading.
Filter at a temperature between 300ºF (149ºC) and
375ºF (191ºC).
E71
OQS TEMP LOW
Oil temperature is too low for a valid OQS reading.
Filter at a temperature between 300ºF (149ºC) and
375ºF (191ºC).
E72
TPM RANGE LOW
The TPM is too low for a valid OQS reading. The
incorrect oil type may be selected in the setup menu.
The sensor may not be calibrated for the oil type. See
oil type chart.
E73
TPM RANGE HIGH
The TPM reading is too high for a valid OQS reading.
Dispose the oil.
E74
OQS ERROR
The OQS has an internal error. Power cycle the
entire fryer battery. Check to see if OQS software
version appears.
E75
OQS AIR ERROR
The OQS is detecting air in the oil. Check the O-rings
and check/tighten prescreen filter to ensure no air is
entering the OQS sensor.
E76
OQS ERROR
The OQS sensor has a communication error. Check
connections to the OQS sensor. Power cycle the
entire fryer battery.
E77-E80 N/A
N/A
Содержание Frymaster FilterQuick 2FQG30U
Страница 8: ...1 3 ...
Страница 41: ...1 36 1 16 2 Bulk Wiring ...
Страница 56: ...1 51 1 18 6 Clogged Drain Failed Oil Sensor Error Flowchart ...
Страница 57: ...1 52 1 18 7 Menu Trees 1 18 7 1 FilterQuick Controller Setup Menu Tree ...
Страница 58: ...1 53 1 18 7 2 FilterQuick Filter and Info Mode Menu Tree ...
Страница 62: ...1 57 1 20 Principal Wiring Connections ...
Страница 63: ...1 58 1 21 Wiring Diagrams 1 21 1 Main FQG 230 430 120V CE Export ...
Страница 64: ...1 59 1 21 2 Main FQG 230 430 Australia ...
Страница 65: ...1 60 1 21 3 Main FQG 230 430 120V CE Export with Solid Shortening ...
Страница 66: ...1 61 1 21 4 Main FQG 230 430 Australia with Solid Shortening ...
Страница 67: ...1 62 1 21 5 Main FQG 330 530 120V CE Export ...
Страница 68: ...1 63 1 21 6 Main FQG 330 530 Australia ...
Страница 69: ...1 64 1 21 7 Main FQG 330 530 120V CE Export with Solid Shortening ...
Страница 70: ...1 65 1 21 8 Main FQG 330 530 Australia with Solid Shortening ...
Страница 71: ...1 66 1 21 9 Transformer Filter Box 430 530 ...
Страница 72: ...1 67 1 22 Simplified Wiring Diagrams 1 22 1 FilterQuick FQG30 Series Simplified Wiring with Push Pull Handles ...
Страница 73: ...1 68 1 22 2 FilterQuick FQG30 Series Simplified Wiring with Push Buttons ...
Страница 74: ...1 69 1 22 3 FilterQuick FQG30 Series Data Network Flowchart ...
Страница 76: ...1 71 1 24 Shortening Melting Unit Wiring Diagram ...
Страница 77: ...1 72 1 25 Modular Basket Lift Wiring Diagram 100 120V 1 2 4 3 5 6 12 7 8050518E ...
Страница 79: ...1 74 1 27 Basket Lift Interface Harness ...