1-37
1.16.3 Frymaster FilterQuick™ Fryer and Bulk Oil System Plumbing Schematic
Check
Valve
Bulk Oil
Manifold
Solenoid
Valve
Check
Valve
Top-0ff
Pump
Top-0ff
Jug
New Oil Pump
Return
Valves
Frypots
Drain
Ball
Valves
Built-in Filter Pan
Fryer
Filter
Pump
Bypass
Check
Valve
Filter Pump
Check Valve
Manual
Dispose
Valve
Waste Oil
Tank
New Oil
Tank
1.16.4 Bulk Oil Test Quick Reference
DISPOSE TO WASTE, REFILL VAT FROM BULK:
1.
Hold down “Filter” button until controller beeps twice.
2.
Scroll to “Dispose” using “Right Arrow" button then press “
” button.
3.
“Dispose? Yes/No” is displayed.*
4.
Press “Yes” to dispose of oil in pot.
5.
“Start Dispose” is displayed with blinking LED.
6.
Pull the drain handle
7.
“Draining” followed by “Flushing” is displayed.
8.
“Vat Empty? Confirm” is displayed.
9.
Press “Confirm”.
10.
“Close Drain” is displayed with blinking LED.
11.
Push the drain handle in towards the fryer.
12.
“Open Dispose Valve” is displayed.
13.
Open dispose valve by pulling completely forward to start disposal.
14.
“Disposing” is displayed for four minutes.
15.
“Remove Filter Pan” is displayed.
16.
Slide the filter pan slightly out of the fryer.
17.
“Is Pan Empty? Yes No” is displayed.
18.
Press “Yes” if filter pan is empty. Select “No” if pan still has oil in it.
19.
“Insert Filter Pan” is displayed.
20.
Insert the filter pan.
21.
“Close Dispose Valve” is displayed.
Bulk Oil Company
Components
Fryer Components
Содержание Frymaster FilterQuick 2FQG30U
Страница 8: ...1 3 ...
Страница 41: ...1 36 1 16 2 Bulk Wiring ...
Страница 56: ...1 51 1 18 6 Clogged Drain Failed Oil Sensor Error Flowchart ...
Страница 57: ...1 52 1 18 7 Menu Trees 1 18 7 1 FilterQuick Controller Setup Menu Tree ...
Страница 58: ...1 53 1 18 7 2 FilterQuick Filter and Info Mode Menu Tree ...
Страница 62: ...1 57 1 20 Principal Wiring Connections ...
Страница 63: ...1 58 1 21 Wiring Diagrams 1 21 1 Main FQG 230 430 120V CE Export ...
Страница 64: ...1 59 1 21 2 Main FQG 230 430 Australia ...
Страница 65: ...1 60 1 21 3 Main FQG 230 430 120V CE Export with Solid Shortening ...
Страница 66: ...1 61 1 21 4 Main FQG 230 430 Australia with Solid Shortening ...
Страница 67: ...1 62 1 21 5 Main FQG 330 530 120V CE Export ...
Страница 68: ...1 63 1 21 6 Main FQG 330 530 Australia ...
Страница 69: ...1 64 1 21 7 Main FQG 330 530 120V CE Export with Solid Shortening ...
Страница 70: ...1 65 1 21 8 Main FQG 330 530 Australia with Solid Shortening ...
Страница 71: ...1 66 1 21 9 Transformer Filter Box 430 530 ...
Страница 72: ...1 67 1 22 Simplified Wiring Diagrams 1 22 1 FilterQuick FQG30 Series Simplified Wiring with Push Pull Handles ...
Страница 73: ...1 68 1 22 2 FilterQuick FQG30 Series Simplified Wiring with Push Buttons ...
Страница 74: ...1 69 1 22 3 FilterQuick FQG30 Series Data Network Flowchart ...
Страница 76: ...1 71 1 24 Shortening Melting Unit Wiring Diagram ...
Страница 77: ...1 72 1 25 Modular Basket Lift Wiring Diagram 100 120V 1 2 4 3 5 6 12 7 8050518E ...
Страница 79: ...1 74 1 27 Basket Lift Interface Harness ...