Overview of Error Blink Codes
•
243
Auxiliary
Commands
WAGO-I/O-SYSTEM 750
I/O Modules
Address
Configuration
variable
Dec. Hex.
Data
type
Default Range
Description
Current_Ratio_
Stop
61
0x3D UINT8 100
0 ... 150
Current factor for STOP mode in [%],
based on motor rated current "Current"
Setup
Acceleration
62
0x3E
UINT16 10
0 ... 32767
Acceleration for JOG and Reference
mode
Rotary_Axis_
Period
64 0x40 INT32 0
0
...
16777216
Sets the period P for a rotary axis; zero
is entered here for a linear axis.
Drive_Range_
Neg
68 0x44 INT32 -0x7fffff 0
Acceptable moving range in negative
direction
Drive_Range_
Pos
72
0x48
INT32
0x7fffff 0
Acceptable moving range in positive
direction
Reserved_76 76
0x4C
UINT32
0
Reserved
Reserved_80 80
0x50
UINT32
0
Reserved
84
0x54
Camshaft_Ch9_
Start
88 0x58 INT32 0
±8388607 Camshaft
channel 9 position, starting
edge
Camshaft_Ch9_
Period
92 0x5B INT32 100 1
...
8388607
Camshaft channel 9 period
Camshaft_Ch9_
Pulsewidth
96 0x60 INT32 50
0
...
8388607
Camshaft channel 9 pulse width
Braketime_Turn_
On
100 0x64 UINT32 0
1
...
8388607
Starting time for brake in [ms]
Braketime_Turn_
Off
104 0x68 UINT32 0
0
...
8388607
Switch-off time for brake in [ms]
Reference_Offset 108 0x6C UINT32 0
±8388607
Position of reference switch