![WAGO I/O SYSTEM 750 750-671 Скачать руководство пользователя страница 103](http://html1.mh-extra.com/html/wago/i-o-system-750-750-671/i-o-system-750-750-671_manual_3328297103.webp)
750-671 [Steppercontroller]
•
103
Positioning
WAGO-I/O-SYSTEM 750
I/O Modules
2.1.2.11.1.7.4
Autostart
An existing Move program is started automatically after a module reset when
the configuration bit HwSwConfig.Program_AutoStart (Bit 7) is set.
Prerequisites for successful automatic start:
Valid Move program present in EEPROM,
The HwSwConfig.Program_AutoStart bit is set in the configuration,
The Rest status bit is set and has not yet been canceled,
The Ready status bit is set,
The Stop_N_ACK status bit is set.
A Move program started by HwSwConfig.Program_AutoStart can be ended
by canceling Reset. The bit is reset by Reset_Quit.
A Move program is started only one time after each reset by
HwSwConfig.Program_AutoStart.
A Move program started with HwSwConfig.Program_AutoStart is always
started at an address of 0.