Reference Commands for Move Mode
•
175
Setpoint
commands
WAGO-I/O-SYSTEM 750
I/O Modules
3.2.4.1.12
SET_ACC_MODE (0x21)
Set the type of acceleration and delay; valid as of the next positioning process.
Request
Byte 2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
MB0
0x40
MB1 T
-
MB2
0x21
MB3 DEC_M DEC_T ACC_M ACC_T
MB4 Reserved
MB5 Reserved
0: constant
acceleration
1: linear increase in acceleration
With ACC_M = 0, the period for acceleration increase is
Acc_ParamUp, the increase in acceleration is calculated at
ACC_M <> 0.
2: sin^2 increase in acceleration
With ACC_M = 0, the period for acceleration increase is
Acc_ParamUp, the increase in acceleration is calculated at
ACC_M <> 0.
ACC_T
3: Reserved
0: no
modification
1: Acc_ParamUp
interpreted as the acceleration period
2: Acc_ParamUp interpreted as the acceleration path
ACC_M
3: Reserved
0: constant
deceleration
1: linear
deceleration
With DEC_M = 0, the period for deceleration is Acc_ParamDown,
the increase in deceleration is calculated at DEC_M <> 0.
2: sin^2
deceleration
With DEC_M = 0, the period for deceleration is Acc_ParamDown,
the increase in deceleration is calculated at DEC_M <> 0.
DEC_T
3: Reserved
0: no
modification
1: Acc_ParamDown
interpreted as the deceleration period
2: Acc_ParamDown interpreted as the deceleration path
DEC_M
3: Reserved