![WAGO I/O SYSTEM 750 750-671 Скачать руководство пользователя страница 70](http://html1.mh-extra.com/html/wago/i-o-system-750-750-671/i-o-system-750-750-671_manual_3328297070.webp)
70 •
750-671 [Steppercontroller]
Configuration
WAGO-I/O-SYSTEM
750
I/O
Modules
Fig. 2.1.2-13: Low pass 500ms
p067022x
Pulse extension sets the output on an input 0
1 edge. The output is reset
when the set time expires after the 1
0 edge. Retriggering during the runtime
is possible.
Fig. 2.1.2-14: Pulse extension 500ms
p067023x
The monoflop function sets the output on an input 0
1 edge. The output is
reset after the set time expires. Retriggering during the runtime is not possible.