750-671 [Steppercontroller]
Configuration
WAGO-I/O-SYSTEM
750
I/O
Modules
Bit 1:
0: Reference run to reference switch
1: Reference run to limit switch
Bit 2:
0: Reference run to negative end of a reference switch
1: Reference run to positive end of a reference switch
Bit 3 ... 7: Reserved
2.1.2.10.1.1.5
Jog Mode
Acc_Fact, Offset 44, Range [1 ... 25000]
Default setup speed.
The current moving speed is used when this parameter is 0.
Acc_Fact, Offset 62, Range [0 ... 32767]
Acceleration for Jog mode and Referencing.
2.1.2.10.1.1.6
Ramps
Acceleration_Stop_Fast, Offset 46, Range [0 ... 32767]
Default acceleration for STOP mode; the current acceleration is used when
this parameter is 0.
Acceleration_RampUp, Offset 48, Range [0 ... 32767]
Default acceleration for acceleration phase.
Acceleration_RampDown, Offset 50, Range [0 ... 32767]
Default acceleration for delay phase.
Acceleration_RampUp_Param, Offset 52,
Range [0 ... 16777216]
Default acceleration time or acceleration path
Acceleration_RampDown_Param, Offset 56,
Range [0 ... 16777216]
Default deceleration time or deceleration path
Acceleration_Modes, Offset 60