Overview of Error Blink Codes
•
223
Auxiliary
Commands
WAGO-I/O-SYSTEM 750
I/O Modules
Bit number
Default
Name
Dec.
Hex.
Type
Target/Source Bit no.
Description
Move program mode
0: The Move program mode is not active
(selected).
M_Program_
ACK
20 0x14 SRC KBUS_ST1_4
0x84
1: The Move program mode is active. The
Move program is started with the first
command on the next rising edge for
Start.
Reference run mode
0: The Reference run mode is not active
(selected).
M_
Reference_
ACK
21 0x15 SRC KBUS_ST1_5
0x85
1: The Reference run mode is active and the
drive is started at the setup speed on the
next rising edge for Start.
Jog mode
0: The Jog mode is not active (selected).
M_Jog_ACK 22 0x16 SRC KBUS_ST1_6 0x86
1: The Jog mode is active.
Mailbox mode
0: The Mailbox mode is not active
(selected).
M_DriveBy
Mbx_ACK
23 0x17 SRC KBUS_ST1_7
0x87
1: The Mailbox mode is active.
Brake
0: The brake is not released.
Brake 24
0x18
SRC
-
-
1: The brake is released.
ERR_Code
25
0x19
SRC
LED H
0xD3 This bit is normally linked with an LED. If an
error is present, it is output as a blink code.
Setup mode is active.
When this bit is set the drive speed is limited to
the defined setup speed. Acceleration is not
limited. The currently valid acceleration value
is applied.
0: Setup mode is not active.
SetupSpeed_
Active_ACK
26 0x1A SRC KBUS_ST3_6
0x96
1: Setup mode is active.
Program
Running
27
0x1B
SRC
A Move program is currently in progress.
Ramp_Up 28 0x1C
SRC
-
- Set
during the acceleration phase
Ramp_Down 29
0x1D SRC
-
-
Set during the deceleration phase
30
0x1E