234 •
Overview of Error Blink Codes
Auxiliary
Commands
WAGO-I/O-SYSTEM
750
I/O
Modules
Bit number
Default
Name
Dec.
Hex.
Type
Target/Source Bit no.
Description
Limit switch input on movement in negative
direction.
This bit is linked to the internal bus.
0:
The negative direction limit switch is not
actuated.
LimitSwitch_
Neg
193 0xC1 DST/
SRC
KBUS_CTRL3
_5
1:
The negative direction limit switch is
actuated. The drive is being run down.
Drive Stop 1 inverted
This bit is linked to Input 1 of the module.
The return message is transmitted via
Stop_N_ACK bit. Stop1_N and Stop2_N are
always taken into account at that bit.
0:
Current is being supplied to the motor,
but it is at standstill. If the motor is still
turning it is put into standstill by the
STOP acceleration command. The motor
cannot be started-up.
Stop1_N 194
0xC2
DST/
SRC
Input1 0x30
1:
The drive may be started.
Brake_
Manual
195 0xC3 DST/
SRC
ZERO
0x00
Manual control of brake