Function Parameter Table VD560 Series Inverter User Manual
- 66 -
Second Time
Fault
F9-23
Frequency Upon
the First Time
Fault
-
-
●
F9-24
Current Upon
the First Time
Fault
-
-
●
F9-25
Bus Voltage
Upon the First
Time Fault
-
●
F9-26
Input Terminal
State Upon the
First Time Fault
-
●
F9-27
Output Terminal
State Upon the
First Time Fault
-
-
●
F9-28
Inverter State
Upon the First
Time Fault
-
-
●
F9-29
Power on Time
Upon the First
Time Fault
-
-
●
F9-30
Running Time
Upon the First
Time Fault
-
-
●
F9-33
Fault Automatic
Reset Times
0~20
0
○
F9-34
Fault Automatic
Reset Interval
Time
0.1s~100.0s
1.0s
○
F9-35
Fault DO Action
Selection During
the Fault
Automatic Reset
0: No action
1: Action
0
○
F9-36
Fault Protection
Action Selection
1
Unit’s digit: motor overload (11)
0: Coast to stop
1: Stop according to stop mode
2: Continue to run
Ten’s digit: input phase loss (13)
0: Coast to stop
1: Stop according to stop mode
2: Continue to run
Hundred’s digit: output phase loss (14)
0: Coast to stop
1: Stop according to stop mode
0x00000
○