VD560 Series Inverter User Manual Function Parameter Table
- 85 -
A2-17
Encoder Line
Number
1~65535
2000
◎
A2-18
Encoder Type
0: ABZ incremental encoder
1: Rotating transformer
0
◎
A2-20
ABZ Incremental
Encoder AB
Sequance
0: Forward
1: Reverse
0
◎
A2-21
Encoder
Mounting Angle
0.0
~
359.9
0
0.0
0
◎
A2-24
Pole Pairs of
Rotating
Transformer
1~1000
1
◎
A2-25
Speed Feedback
PG
Disconnection
Detection TIme
0.0: No action
0.1s~10.0s
0.0s
◎
A2-26
Tune Selection
0: No operation
1: Asynchronous motor static tuning
2: Asynchronous motor complete tuning
0
◎
A3 Motor 2 Vector Control Parameters
Function
Code
Parameter
Name
Setting Range
Factory
Default
Value
Property
A3-00
Speed Loop
Proportion Gain
1
1~100
30
○
A3-01
Speed Loop
Integral Time 1
0.01s~10.00s
0.50s
○
A3-02
Switching
Frequency 1
0.00Hz~A6-05
5.00Hz
○
A3-03
Speed Loop
Proportion Gain
2
1~100
20
○
A3-04
Speed Loop
Integral Time 2
0.01s~10.00s
1.00s
○
A3-05
Switching
Frequency 2
A6-02~max frequency
10.00Hz
○
A3-06
Vector Control
Slip
Compensation
Gain
20%~200%
100%
○
A3-07
Speed Loop
Filter Time
Constant
0.000s~0.100s
0.000s
○