Parameter Description VD560 Series Inverter User Manual
- 174 -
Reference 13
FC-46
Run Time of Simple PLC
Reference 14
0.0s (h)~6553.5s (h)
0.0s (h)
○
FC-47
Acceleration
/Deceleration Time
Selection of Simple PLC
Reference 14
0~3
0
○
FC-48
Run Time of Simple PLC
Reference 15
0.0s (h)~6553.5s (h)
0.0s (h)
○
FC-49
Acceleration
/Deceleration Time
Selection of Simple PLC
Reference 15
0~3
0
○
FC-50
Simple PLC Run Time
Unit
0: s
1: h
0
○
FC-51
Multi-reference 0 Setting
Method
0: Coding FC-00 given
1: AI1
2: AI2
3: AI3 (expansion card)
4: PULSE
5: PID
6: Preset frequency(F0-09)given,
UP/DOWN can modify
7: Keypad potentiometer
0
○
This parameter decision the given channel of multi-reference 0.
In addition to FC-00, there are a variety of other options to convenient switching between
multi-reference and other given way. When the multi-reference is used as a frequency source or
simple PLC as a frequency source, can be easy to implement the switching between two kinds of
frequency source.
FC-52
MS Speed
Acceleration/Deceleratio
n Time Selection Mode
0: Function code confirm
1: Terminal confirm
0
○
Selection MS speed acceleration and deceleration time. Can be determined by the simple PLC
corresponding to each of the acceleration and deceleration time, can also can 4 stage acceleration
and deceleration time selected by the DI terminal (you can refer to the acceleration and deceleration
time selection terminal functional specification in schedule 2 of F5 group).
Fd Communication Parameter Group
Please refer to chapter 9 communication protocol.
Содержание VD560 Series
Страница 2: ......
Страница 9: ...VD560 Series Inverter User Manual Safety and Precautions 5 damage or performance reduce...