VD560 Series Inverter User Manual Function Parameter Table
- 91 -
Terminal state
setting
0: Disabled
1: Enabled
Ten’s digit: virtual VDI2, same as above
Hundred’s digit: virtual VDI3, same as
above
Thousand’s digit: virtual VDI4, same as
above
Ten thousand’s digit: virtual VDI5, same
as above
b1-07
Function
Selection when
AI1 Terminal as
DI
0~59
0
◎
b1-08
Function
Selection when
AI2 Terminal as
DI
0~59
0
◎
b1-09
Function
Selection when
AI3 (expansion
card) Terminal
as DI
0~59
0
◎
b1-10
Effective Mode
Selection when
AI1 Terminal as
DI
Unit’s digit: AI1
0: High electrical level enable
1: Low electrical level enable
Ten’s digit: AI2, same as above
Hundred’s digit: AI3 (expansion card),
same as above
0x000
◎
b1-11
Virtual VDO1
Output Function
Selection
0: Short circuit with physical DIX internal
1~43: see the F6 group physical DO
output selection
0
○
b1-12
Virtual VDO2
Output Function
Selection
0: Short circuit with physical DIX internal
1~43: see the F6 group physical DO
output selection
0
○
b1-13
Virtual VDO3
Output Function
Selection
0: Short circuit with physical DIX internal
1~43: see the F6 group physical DO
output selection
0
○
b1-14
Virtual VDO4
Output Function
Selection
0: Short circuit with physical DIX internal
1~43: see the F6 group physical DO
output selection
0
○
b1-15
Virtual VDO5
Output Function
Selection
0: Short circuit with physical DIX internal
1~43: see the F6 group physical DO
output selection
0
○
b1-16
VDO1 Closing
Delay
0.0s~3600.0s
0.0s
○