Function Parameter Table VD560 Series Inverter User Manual
- 68 -
0: Coast to stop
1: Stop according to stop mode
2: Continue to run
Thousand’s digit: offload (37)
0: Coast to stop
1: Stop according to stop mode
2: Decelerate to 7% of the rated motor
frequency continue running, automatically
restored to the set frequency operation
when no offload
Ten thousand’s digit: PID feedback lost
when running (18)
0: Coast to stop
1: Stop according to stop mode
2: Continue to run
F9-40
Continue
Running
Frequency
Selection at
Failure
0: Run to the current running frequency
1: Run at set frequency
2: Run at frequency upper limit
3: Run at frequency lower limit
4: Run at abnormal standby frequency
0
○
F9-41
Abnormal
Standby
Frequency
60.0%~100.0%
(100.0% corresponding max frequency
F0-10)
100.0%
○
FA Process PID
Function
Code
Parameter
Name
Setting Range
Factory
Default
Value
Property
FA-00
PID Given
Source
0: FA-01 setting
1: AI1
2: AI2
3: AI3 (expansion card)
4: PULSE setting
5: Communication setting
6: Multi-reference setting
7: Keypad potentiometer
0
○
FA-01
PID Digital
Giving
0.0%~100.0%
50.0%
○
FA-02
PID Feedback
Source
0: A1
1: AI2
2: AI3 (expansion card)
3: AI1-AI2
4: PULSE setting
5: Communication setting
0
○