2.3.2.5
AI1 signal inversion
ID387
2.3.3.5
AI2 signal inversion
ID398
Signal inversion function is useful in situation when e.g. PLC is sending power limit to
the drive by using analogue inputs, if PLC is unable to communicate to the drive power
limit would be normally zero, by using inverted signal logic zero value from PLC would
mean maximum power limit thus allowing drive running e.g. from keypad without
changing power limit function parameters.
0 = No inversion
1 = Signal inverted
AI3/AI4 Output
Analogue
Input
100 %
0 %
40 %
Custom
Min
80 %
Custom
Max