© 2019 TOSS GmbH & Co. KG -Verpackungssysteme- Alle Rechte vorbehalten! Nachdruck, auch auszugsweise, ohne unsere schriftliche Genehmigung nicht gestattet!
27
5.7. Controller setting menu
Line 1
C O N T R O L L E R S E T T I N G
Line 2
T c s e t t i n g
Line 3
T e m p e r a t u r e s e t t i n g
Line 4
T i m e s e t t i n g
Line 5
C a l . s e t t i n g
Line 6
S e t v a l u e s e t t i n g
Line 7
Line 8
Press the button to return to the Selection menu (
5.3.).
Line 1:
Menu name
Line 2:
Menu item “Tc setting” menu for the regulator (
5.7.1.)
Line 3:
Menu item “Temperature setting” menu for the regu-
lator (
5.7.2.)
Line 4:
Menu item “Time setting” menu for the regulator (
5.7.3.)
Line 5:
Menu item “Calibration setting” menu for the regula-
tor (
5.7.4.)
Line 6:
Menu item “Set value setting” menu for the control-
ler (
5.7.5.)
5.7.1. Tc settings menu
Line 1
T C - S E T T I N G
Line 2
A l l o y L
Line 3
A l l o y A 2 0
Line 4
N o r e x
Line 5
A l l o y M
Line 6
v a r . T c s e t t i n g
Line 7
Line 8
Press the button to return to the Regulator settings menu
(
5.7.).
Line 1:
Menu name
Line 4…7:
Options for the four definite Tc settings of the
regulator via the material designation.
Line 8:
Selection and menu item (
5.7.1.1.) for the varia-
ble Tc-setting. The variable Tc setting is also possible if it is
not activated. Press the button to switch to the menu.
5.7.1.1. Variable Tc settings menu
Line 1
V A R . T C S E T T I N G
Line 2
T c 1 :
8 . 8 8 8 x 1 0 - 3
Line 3
3 - 9 9 . 9 9 x 1 0 - 4
Line 4
T c 2 : ± 8 8 . 8 8 x 1 0 - 6
Line 5
0 - ± 9 9 . 9 9 x 1 0 - 6
Line 6
T c 3 : ± 8 8 . 8 8 x 1 0 - 9
Line 7
0 - ± 9 9 . 9 9 x 1 0 - 9
Line 8
T e m p . S : 8 8 8
°
C D : 8 8 8
°
C
Press the button
to return to the Tc-settings menu (
5.7.1.).
Line 1:
Menu name
Line 2…3:
Setting of the Tc1 value. The adjustable range is
shown in line 3.
Line 4…5:
Setting of the Tc2 value. The adjustable range is
shown in line 5.
Line 6…7:
Setting of the Tc3 value. The adjustable range is
shown in line 7.
Line 8:
The controller PIREG-D2 will calculate automatically
the maximum temperature for the continuity (S) and dynam-
ic (D) resistance behavior of the heater band for each varia-
ble Tc setting. In any case the set temperature range must
be lower than the temperature value for continuity (S) and
dynamics (D).
5.7.2. Temperature settings menu
Line 1
T E M P E R A T U R E S E T T I N G S
Line 2
T e m p e r a t u r e
2 0 0
C
Line 3
r a n g e : 3 0 0
C
Line 4
4 0 0
C
Line 5
5 0 0
C
Line 6
1 0 0 - 5 0 0 ° C
8 8 8
C
Line 7
R e f e r e n c e
8 8
C
Line 8
t e m p e r a t u r e : 0 - 5 0 ° C
Press the button to return to the Regulator settings menu
(
5.7.).
Line 1:
Menu name
Line 2…5:
Options for preset temperature ranges.
Line 6:
Selection and setting item for the variable tempera-
ture range. The variable temperature range can also be set
if it was not selected. The admissible setting range is shown
on the left half.
Line 7…8:
Setting of the variable calibration reference tem-
perature. The admissible setting range is shown in line 8 in
the right half of the screen.
5.7.3. Time settings menu
Line 1
T I M E S E T T I N G S
Line 2
P r e h e a t .
O f f
2 s
Line 3
r a m p : 1 s 5 s
Line 4
Line 5
C a l i b r a t i o n
1 5 s
Line 6
c o m p a r e t i m e : 3 0 s
Line 7
T c - c o r r e c t i o n 8 8 8 s
Line 8
H e a t i n g t i m e : 1 - 9 9 9 s
Press the button to return to the Regulator settings menu
(
5.7.).
Line 1:
Menu name
Line 2…3:
Options for the heating ramp duration.
Line 5…6:
Options for the calibration comparison time.
Line 7…8:
Adjustment of the heating time for automatic
temperature coefficient correction with the external ther-
mometer exTM. With “Off” the temperature coefficient cor-
rection must be controlled manually. The admissible setting
range is shown in line 8 on the right hand side of the
screen.