18
5. Menu structure
5.1. Switching on
Line 1
Line 2
Line 3
Line 4
Line 5
Line 6
G m b H & C o . K G
Line 7
D - 3 5 4 1 8 A l t e n - B u s e c k
Line 8
0 6 4 0 8 / 9 0 9 1 - 0
After switching the display unit on, the initial screen will be
displayed for 2 seconds before the Working menu is called
automatically (
5.2.).
Line 1…4:
Logo of the Toss company
Line 6:
Legal form of the Toss company
Line 7:
Seat of the company incl. zip code and town
Line 8:
Telephone number of the Toss company
5.2. Working menu
5.2.1. Working menu without sequence control
Line 1
T a r g . :
8 8 8
C
M e n u
Line 2
0 - 3 0 0
C
H e a t .
Line 3
A c . V . :
8 8 8
C
C a l .
Line 4
R e s e t
Line 5
Line 6
C y c l e T . : 8 8 8 . 8 s
Symbol
field
Line 7
Line 8
5.2.2. Working menu with sequence
control
Line 1
T a r g . :
8 8 8
C
M e n u
Line 2
0 - 3 0 0
C
S t a r t
Line 3
A c . V . :
8 8 8
C
C a l .
Line 4
R e s e t
Line 5
Line 6
C y c l e T . : 8 8 8 . 8 s
Symbol
field
Line 7
We l d . T . : 8 8 . 8 s
Line 8
C o o l . P . : 8 8 8
C
Line 1…2:
Display and adjustment of the desired value as
numerical value. The adjustable desired value range is
shown in line 2.
Line 3…4:
Actual value display; when the Hold mode is
activated “Hold” is displayed in line 4 as long as the actual
value is maintained.
When the external thermometer exTM is connected the
measured value of the thermometer exTM “888.8°C” is dis-
played in line 4 during standard and single-point tempera-
ture coefficient correction.
Line 1…4:
Four items for selection are displayed on the
right half. Click the “Menu” menu item to call the Selection
menu (
5.3.). If the locking was activated then the text
„####“ will be shown instead of the text “Menu”.
The following option “Heat.” or “Start” is only available if the
Start function (
5.4.2.) was activated.
- without sequence control:
Select the “Heat” option to
execute a manual welding process and keep the
Ok
button
pressed.
- with sequence control:
If the Start function “Start welding
cycle” is selected for the sequence control, a welding cycle
will be started manually with the “Start” selection point. If
“Heating only” is selected for the Start function a welding
process will be executed manually with the “Weld” option as
long as the
Ok
button is pressed.
The “Cal.” menu item calls up the Calibration selection
menu (
5.2.5.).
Select “Reset” to reset the display unit and the controller.
Line 5:
Bar chart of the actual value.
Line 6:
Display of the cycle time, i.e. the duration
(0…999.9s) of the last welding process or welding cycle.
During automatic temperature coefficient correction with the
thermometer exTM the ending TC correction heating time is
displayed instead of the cycle time.
Line 6…8:
A symbol field for the operating status is shown
on the right half. This symbol field can be selected in the
case of an alarm and an Error menu (
5.2.4.) with an error
description and possible corrective actions will be displayed.
- with sequence control:
Line 7:
Welding time of the sequence control; the numerical
value can be changed either in the Working menu or in the
Welding menu (
5.4.4.). The value of the ending welding
time which – depending on the setting - is counted up or
down can be displayed here during the welding process.
Line 8:
Cooling phase of the sequence control; the value
can be changed either in the Working menu or in the Cool-
ing Phase menu (
5.4.5.).
The value of the ending cooling time which – depending on
the setting - is counted up or down during the cooling pro-
cess is displayed here. This requires that the cooling time
was selected for the cooling phase.