© 2019 TOSS GmbH & Co. KG -Verpackungssysteme- Alle Rechte vorbehalten! Nachdruck, auch auszugsweise, ohne unsere schriftliche Genehmigung nicht gestattet!
26
5.6.1.4. Relay Outputs status menu
Line 1
R E L A Y O U T P U T S T A T U S
Line 2
M e s s a g e r e l a y 1 o
Line 3
C o n t r o l r e l a y 1 o
Line 4
C o n t r o l r e l a y 2 o
Line 5
A l a r m r e l a y o
Line 6
Line 7
Line 8
Press the button
to return to the Relay settings menu (
5.6.1.). If the relay is not actuated an empty circle (o) is
displayed, if the relay is actuated a filled circle (
) is dis-
played.
Line 1:
Menu name
Line 2:
Status message relay 1
Line 3:
Status control relay 1
Line 4:
Status control relay 2
Line 5:
Status alarm relay
5.6.2. Input setting menu
Line 1
I N P U T S E T T I N G
Line 2
P r e h e a t i n g i n p u t
Line 3
S t a r t i n p u t
Line 4
C a l . - S t a r t i n p u t
Line 5
R e s e t i n p u t
Line 6
Line 7
Line 8
Press the button to return to the In-/Output settings menu
(
5.6.).
Line 1:
Menu name
Line 2:
Menu item “Preheating input setting” (
5.6.2.1.)
Line 3:
Menu item “Start input setting” (
5.6.2.2.)
Line 4:
Menu item “Cal.-Start input setting” (
5.6.2.2.)
Line 5:
Menu item “Reset input setting” (
5.6.2.3.)
5.6.2.1. Preheating input setting menu
Line 1
P R E H E A T I N G I N P U T
Line 2
P r e h e a t i n g
Line 3
M e a s u r e m e n t p a u s e
Line 4
C a l . - c h a n g i n g
Line 5
D e l a y : 8 8 . 8 s
Line 6
0 - 9 9 . 9 s
Line 7
Line 8
Press the button
to return to the Input settings menu (
5.6.2.).
Line 1:
Menu name
Line 2:
Selection item Preheating input
Line 3:
Selection item Measurement pause input
Line 4:
Selection item Calibration switching input
Line 5…6:
Setting of the delay time for the calibration
switching. During the delay time the controller prforms a
measurement pause. At Line 5 the adjustable range is
showed.
5.6.2.2. Start input setting menu
Line 1
S T A R T I N P U T
Line 2
S t a r t
Line 3
M e a s u r e m e n t p a u s e
Line 4
C a l . - c h a n g i n g
Line 5
D e l a y : 8 8 . 8 s
Line 6
0 - 9 9 . 9 s
Line 7
Line 8
Press the button
to return to the Input settings menu (
5.6.2.).
Line 1:
Menu name
Line 2:
Selection item Start input
Line 3:
Selection item Measurement pause input
Line 4:
Selection item Calibration switching input
Line 5…6:
Setting of the delay time for the calibration
switching. During the delay time the controller prforms a
measurement pause. At Line 5 the adjustable range is
showed.
5.6.2.3. Calibration-Start input setting menu
Line 1
C A L . - S T A R T I N P U T
Line 2
C a l . - S t a r t
Line 3
M e a s u r e m e n t p a u s e
Line 4
C a l . - c h a n g i n g
Line 5
D e l a y : 8 8 . 8 s
Line 6
0 - 9 9 . 9 s
Line 7
Line 8
Press the button
to return to the Input settings menu (
5.6.2.).
Line 1:
Menu name
Line 2:
Selection item Calibration-Start input
Line 3:
Selection item Measurement pause input
Line 4:
Selection item Calibration switching input
Line 5…6:
Setting of the delay time for the calibration
switching. During the delay time the controller prforms a
measurement pause. At Line 5 the adjustable range is
showed.
5.6.2.4. Reset input setting menu
Line 1
R E S E T I N P U T
Line 2
R e s e t
Line 3
M e a s u r e m e n t p a u s e
Line 4
C a l . - c h a n g i n g
Line 5
D e l a y : 8 8 . 8 s
Line 6
0 - 9 9 . 9 s
Line 7
Line 8
Press the button
to return to the Input settings menu (
5.6.2.).
Line 1:
Menu name
Line 2:
Selection item Reset input
Line 3:
Selection item Measurement pause input
Line 4:
Selection item Calibration switching input
Line 5…6:
Setting of the delay time for the calibration
switching. During the delay time the controller prforms a
measurement pause. At Line 5 the adjustable range is
showed.