5.6.1.1.1. Message Relay 1 Temperature function menu
Line 1
T E M P E R A T U R E F U N C T I O N
Line 2
T e m p . - O k :
- 8 8 K
Line 3
5 - 9 9 K + 8 8 K
Line 4
S t a b . t i m e : 8 8 . 8 s
Line 5
0 - 9 9 . 9 s
Line 6
H o l d :
O f f
Line 7
O n
Line 8
Press the button
to return to the Message Relay 1 set-
tings menu (
5.6.1.1.).
Line 1:
Menu name
Line 2…3:
Setting of the upper and lower limit of the tem-
perature Ok-range around the desired value. The adjustable
range is shown in line 3.
Line 4…5:
Setting of the stabilisation time of the tempera-
ture Ok message. The adjustable range is shown in line 5.
Line 6…7:
Options for switching the holding function of the
message relay on and off. The relay remains actuated after
a welding cycle up to the start of the following welding cycle.
5.6.1.1.2. Message Relay 1 Sequence function menu
Line 1
S E Q U E N C E F U N C T I O N
Line 2
A c t . w i t h s t a r t s i g .
Line 3
A c t . w i t h t e m p . r e a .
Line 4
A c t . d u r . h e a t . p h a s e
Line 5
A c t . d u r . c o o l . p h a s e
Line 6
C a l i b r a t i o n O k
Line 7
A l a r m
Line 8
T c c o r r . s e q u e n c e
Press the button
to return to the Message Relay 1 set-
tings menu (
5.6.1.1.).
Line 1:
Menu name
Line 2:
Option that the message relay picks up when the
“Start” signal is applied and is released when the cooling
phase has elapsed.
Line 3:
Option that the message relay picks up when the
actual value has reached 95% of the desired value and is
released when the cooling phase has elapsed.
Line 4:
Option that the message relay is actuated during
the heating phase.
Line 5:
Option that the message relay is actuated during
the cooling phase.
Line 6:
Option that the message relay is actuated after a
successful calibration.
Line 7:
Option that the message relay is actuated in the
error state (from V1.00/1.19/1.16/1.10).
Line 8:
Option that the message relay performs the control
message for the temperature coefficient correction (from
V1.00/1.23/1.30/1.25)
5.6.1.1.3. Message Relay 1 Time Pulse function menu
Line 1
T I M E P U L S E F U N C T I O N
Line 2
P r e h e a t . p h . : 8 8 . 8 s
Line 3
0 - 9 9 . 9 s
Line 4
C o o l . p h a s e : 8 8 . 8 s
Line 5
0 - 9 9 . 9 s
Line 6
E n d o f p u l s e
Line 7
Line 8
Press the button
to return to the Message Relay 1 set-
tings menu (
5.6.1.1.).
Line 1:
Menu name
Line 2…3:
Option that the message relay is actuated for the
preset time when the welding process or the welding time is
started. The adjustable range is shown in line 3.
Line 4…5:
Option that the message relay is actuated for the
preset time when the cooling phase (end of the heating
phase) is started. The adjustable range is shown in line 5.
Line 6:
Option that the message relay is actuated for
500ms at the end of the cooling phase.
5.6.1.2. Control Relay 1 and 2 settings menu
Line 1
C O N T R O L R E L A Y ½
Line 2
O f f
Line 3
T e m p . f u n c t i o n
Line 4
S e q u n c e f u n c t i o n
Line 5
T i m e P u l s e f u n c t i o n
Line 6
Line 7
Line 8
Press the button
to return to the Relay settings menu (
5.6.1.). Here, the control relay 1 and 2 can be set.
Line 1:
Menu name
Line 2:
Option “Control relay is deactivated”
Line 3:
Selection and menu items (
5.6.1.2.1.) of the
temperature functions for the control relay.
Line 4:
Selection and menu items (
5.6.1.2.2.) of the se-
quence functions for the control relay.
Line 5:
Selection and menu items (
5.6.1.2.3.) of the time
pulse function for the control relay.