© 2019 TOSS GmbH & Co. KG -Verpackungssysteme- Alle Rechte vorbehalten! Nachdruck, auch auszugsweise, ohne unsere schriftliche Genehmigung nicht gestattet!
21
5.4. Sequence Control menu
Line 1
S E Q U E N C E C O N T R O L
Line 2
P r e h e a t i n g 8 8 8
C
Line 3
S t a r t f u n c t i o n S t a r t
Line 4
S e q . C o n t r o l :
O f f
Line 5
O n
Line 6
S t a r t d e l a y 8 . 8 s
Line 7
We l d . t i m e 8 8 . 8 s
Line 8
C o o l . p h a s e 8 8 8
C
Press the button to return to the Selection menu (
5.3.).
Line 1:
Menu name
Line 2:
Menu item “Preheating” menu (
5.4.1.); the preset
preheating temperature or the status “Off” is displayed on
the right-hand border.
Line 3:
“Start function” menu item (
5.4.2.); the preset
Start function (“Start”/”Heat.”) is displayed on the right-hand
border.
Line 4…5:
Options for switching the sequence control on
and off
Line 6:
Menu item “Start Delay” menu (
5.4.3.); the preset
start delay time or the status “Off” is displayed on the right-
hand border.
Line 7:
Menu item “Welding Time” menu (
5.4.4.); the
preset welding time is displayed on the right-hand border.
Line 8:
Menu item “Cooling Phase” menu (
5.4.5.): the
set parameters (absolute or relative cooling temperature or
cooling time) are displayed on the right-hand border.
5.4.1. Preheat menu
Line 1
P R E H E A T I N G
Line 2
O f f
Line 3
T e m p . : 8 8 8
C
Line 4
4 0 - 3 0 0
C
Line 5
Line 6
Line 7
Line 8
Press the button to return to the Sequence Control menu
(
5.4.).
Line 1:
Menu name
Line 2:
Menu item “Preheat” deactivated
Line 3…4:
Option for activating the preheating and setting
the preheating temperature. The preheating temperature
can also be set when the preheating function is switched
off. The adjustable range is shown in line 4. The maximum
adjustable preheating temperature is a result of the selected
temperature range.
5.4.2. Start Function menu
Line 1
S T A R T F U N C T I O N
Line 2
O f f
Line 3
S t a r t w e l d i n g c y c l e
Line 4
H e a t i n g o n l y
Line 5
Line 6
Line 7
Line 8
Press the button
to return to the Sequence control menu
(
5.4.).
Line 1:
Menu name
Line 2:
Option for deactivating the Start function. No weld-
ing cycle or heating can then be started from the Working
menu.
Line 3:
“Start welding cycle” option; with this setting a weld-
ing cycle which corresponds to the settings in the sequence
control is started with “Start” in the Working menu (
5.2.2.).
Line 4:
“Only heating” option; with this setting a welding
cycle is executed manually with “Heat.” in the Working
menu as long as the button
Ok
is pressed.
5.4.3. Start Delay menu
Line 1
S T A R T D E L A Y
Line 2
O f f
Line 3
S t a r t d e l a y : 8 . 8 s
Line 4
0 - 9 . 9 s
Line 5
Line 6
Line 7
Line 8
Press the button to return to the Sequence Control menu
(
5.4.).
Line 1:
Menu name
Line 2:
Option “Start delay” deactivated
Line 3…4:
Option for activating the “Start delay” and setting
the “Start delay time”. The “Start delay” can also be set
when the “Start delay” function is switched off. The ad-