5.4.4. Welding Time menu
Line 1
WE L D I N G T I M E
Line 2
We l d i n g t i m e :
8 8 . 8 s
Line 3
0 - 9 9 . 9 s E x t e r n
Line 4
S t a r t o f -
w i t h s t a r t
Line 5
w e l d i n g w i t h t e m p .
Line 6
t i m e : r e a c h e d
Line 7
D i s p l a y - O f f U p
Line 8
C o u n t i n g : D o w n
Press the button to return to the Sequence Control menu
(
5.4.).
Line 1:
Menu name
Line 2…3:
Options of the “Welding time” function. Can be
set via the time (line 2) or externally via the “Start” signal.
The welding time is as long as the “Start” signal is applied.
Setting of the welding time: the adjustable range is shown in
line 3.
Line 4…6:
Options for the start conditions of the welding
time if the welding time is controlled via the time. If the func-
tion “when temperature reached” is selected the welding
time will start when the temperature of the heater band ex-
ceeds 95% of the desired value.
Line 7…8:
Options for display counting in the Working
menu (
5.2.2.) during the welding process.
5.4.5. Cooling Phase menu
Line 1
C O O L I N G P H A S E
Line 2
A b s . c o o l t e m p . : 8 8 8
C
Line 3
C o o l i n g t e m p e r a t u r e :
Line 4
A b s o l u t e : 5 0 - 3 0 0
C
Line 5
R e l a t i v e : 4 0 - 1 0 0 %
Line 6
C . o f f t i m e : 0 - 9 9 . 9 s
Line 7
D i s p l a y - O f f U p
Line 8
C o u n t i n g : D o w n
Press the button to return to the Sequence Control menu
(
5.4.).
Line 1:
Menu name
Line 2:
Setting of the selected cooling phase function: ab-
solute cooling temperature, relative cooling temperature and
cooling time. The text on the left hand side and the format of
the setting value on the right hand side are adapted to the
selection.
Line 4:
Option for the Absolute Cooling Temperature func-
tion. The adjustable temperature range is displayed on the
right hand side.
The maximum adjustable absolute cooling temperature is a
result of the selected temperature range.
Line 5:
Option for the Relative Cooling Temperature func-
tion. The adjustable cooling temperature range is displayed
on the right hand side.
Line 6:
Option for the Cooling Time function. The adjusta-
ble time range is displayed on the right hand side.
Line 7…8:
Options for display counting in the Working
menu (
5.2.2.) during the cooling phase when cooling
time was selected.
5.5. Monitoring menu
Line 1
C O N T R O L
Line 2
T e m p . c o n t r . O f f
Line 3
P r e h e a t . c o n t r . O f f
Line 4
S t a r t c o n t r . :
O f f
Line 5
O n
Line 6
Line 7
Line 8
Press the button to return to the Selection menu (
5.3.).
Additional error functions for monitoring the welding process
are set in the Monitoring menu.
Line 1:
Menu name
Line 2:
Menu item “Temperature monitoring” (
5.5.1.);
whether the temperature monitoring is activated or deac-
tivated is displayed on the right-hand border.
Line 3:
Menu item “Preheat monitoring” (
5.5.2); whether
the preheat monitoring is activated or deactivated is dis-
played on the right-hand border.
Line 4…5:
Options for switching the Start monitoring on
and off. The Start monitoring can only be activated when
the sequence control is switched on. If the “Start monitoring”
function is activated the welding cycle will be interrupted as
soon as the “Start” signal is no longer applied (Emergency
Off). If the “Start monitoring" function is deactivated the
welding cycle which was just started will be continued until
the "Start" signal is removed.