5.7.4. Calibration settings menu
Line 1
C A L I B R A T I O N S E T T I N G S
Line 2
T y p e o f N e w
Line 3
c a l . :
S a v e
Line 4
T r a n s f o r -
E I c o r e
Line 5
m e r t y p e : R i n g c o r e
Line 6
T c - c o r r . : O f f
Line 7
O n
Line 8
Press the button to return to the Regulator settings menu
(
5.7.).
Line 1:
Menu name
Line 2…3:
Option for the calibration mode.
Line 4…5:
Option for the transformer type.
Line 6…7:
Options for activating and deactivating the Tc
correction during calibration.
5.7.5. Set value settings menu
Line 1
S E T V A L U E S E T T I N G
Line 2
I n t e r n a l
Line 3
S e t v a l u e i n p u t U
Line 4
S e t v a l u e i n p u t R
Line 5
Line 6
Line 7
Line 8
Press the button to return to the Controller settings menu
(
5.7.).
Line 1:
Menu name
Line 2:
Selection point for the set value setting via the dis-
play unit of the controller.
Line 3:
Selection point for the set value setting via the set
value input of the controller with an analogue voltage.
Line 4:
Selection point for the set value setting via the set
value input of the controller with a set value potentiometer.
The actual value output has the function of the reference
voltage source (10 V).
5.8. Display settings menu
Line 1
D I S P L A Y S E T T I N G
Line 2
L a n g u a g e a . B r i g h t n .
Line 3
H o l d m o d e
Line 4
C o n t r o l
Line 5
T e m p . u n i t : ° C ° F
Line 6
R e l e a s e
Line 7
C y c l e s 8 8 8 8 8 8 8
Line 8
T o t . - C y c l . : 8 8 8 8 8 8 8 8 8
Press the button to return to the Selection menu (
5.3.).
Line 1:
Menu name
Line 2:
Menu item for setting the language and brightness
of the display unit (
5.8.1.)
Line 3:
Menu item “Hold mode” menu of the display unit (
5.8.2.)
Line 4:
Menu item “Control” menu of the display unit (
5.8.3.)
Line 5:
Option for the temperature unit on the display. The
temperature unit is only used for display of the temperature
values. The display unit continues to operate internally with
the unit [°C] even when [°F] is displayed which results in
temperature leaps of 2 °F when the unit [°F] is set as tem-
perature value.
If the thermometer DTM3000 is using as external thermom-
eter exTM, the PIREG-D2 automatically set temperature
unit to the selected temperature unit of the display unit.
When working with the TM6 thermometer the same temper-
ature unit must be set on the thermometer and on the dis-
play unit.
Line 6:
Menu item “Releases menu” of the display unit (
5.8.4.)
Line 7:
Display of the welding cycles carried out. Press the
button
to reset the counter. Press the
Ok
button to reset
the counter to zero.
Line 8:
Display of the total cycle counter of all welding cy-
cles which cannot be reset.
5.8.1. Settings menu for language and brightness
Line 1
L A N G U A G E A . B R I G H T N .
Line 2
D e u t s c h
Line 3
e n g l i s h
Line 4
f r a n c a i s
Line 5
i t a l i a n o
Line 6
N e d e r l a n d s
Line 7
C
J
F
F
8
4
6
Line 8
B r i g h t n e s s : 8 8 8 %
Press the button
to return to the Display settings menu
(
5.8.).
Line 1:
Menu name
Line 2…7:
Options of the display languages of the PIREG-
DIS display unit
Line 8:
Setting the brightness (30…100%) of the display