34
Temperature range
variable setting
0…
nominal
nominal
= 100…500 °C
Under-temp. –10 °C
Over-temperature
nominal
+20 %
Time values (50Hz):
Initialization:
After power on or reset signal:
2 s
Power interruption:
During an interruption to the line voltage, the PIREG-D2
switches to the error state or starts with a reset once the line
voltage has been re-established.
80 ms
Start (heating):
Switch on delay:
35..0.55 ms
Switch off delay:
25..0.45 ms
Preheating
Switch on delay:
25…80 ms
Switch off delay:
25…75 ms
Remanence setting:
After power on, reset and calibration of EI core transformer:
80 ms
After power on, reset and calibration of toroidal core trans-
former:
300 ms
During sealing process with EI core transformers
40 ms
During sealing process with toroidal core transformers
80 ms
During sealing process with toroidal core transformers with
sealing pauses of longer than 10 minutes
160 ms
Current conduction angle of EI core transformer:
3.1 ms
Current conduction angle of toroidal core transformer:
1.8 ms
Calibration start:
Switch on delay:
45..0.55 ms
Calibration:
Max. calibration time temperature reference time= 15 s:
215 s
Max. calibration time temperature reference time= 30 s:
290 s
Temp. reference time 1:
15 s
Temp. reference time 2:
30 s
Reset:
Trigger delay:
55…65 ms
Heat-up Ramp:
without /2 /3 /5 s
Control inputs:
control voltage :
Start (3), calibr. start (25) and reset input (26) are floating
control voltage :
V
contr
= 4…32 VDC (bipolar)
Max. control voltage:
V
contr.max
= ±40 V
Control current:
I
contr.
= 1…12 mA
Supply:
SELV or PELV circuit
Control contact:
Control contact (7) and preheating contact input (19) on the potential of the measuring side
Contact voltage
U
Contact
= 5 V
Contact current:
I
Contact
= 4 mA
Contact type:
potential-free switching contact
Circuit:
SELV or PELV circuit
Set value input:
The input (23) is floating and protected against polarity mismatch
Set value voltage:
V
set
= 0…10 VDC. Depending on the set temp. range, corresponds to:
0...200 °C
0...300 °C
0...400 °C
0...500 °C
0…
nominal
Max. control voltage:
V
set val.max
= ±20 V
Max. input current:
I
inmax
= 20 µA
Input resistance:
R
in
= 1 MΩ
Supply:
SELV or PELV circuit
Voltage measuring input:
Signal voltage (10/11):
V
R
= 1 - 80 V
Max. signal voltage:
V
Rmax
= 120 V
Max. input current:
I
inmax
= 2 mA
Input resistance:
Range 1:
R
in
= 6.4 k
at U
R
= 1…11.3 V
Range 2:
R
in
= 60 k
at V
R
= 11.3 - 80 V
Measurement Category:
CAT II
Supply:
Secondary circuit provides by the mains voltage (see above, Overvoltage
category III). The sealing transformer must be configured according to
EN 61558 (VDE 0570) resp. UL 5085
(isolating transformer with rein-
forced isolation) and UL 61010.
Current measuring input:
Signal current (8/9):
I
R
= 20...400 mA
V
IR
= 0.1 - 2 V
Max. signal current:
I
Rmax
= 500 mA
V
IRmax
= 2.5 V
Input resistance:
R
in
= 5
(ballast resistance)
Measurement Category:
CAT II
Circuit:
SELV or PELV circuit
Actual Value Output:
The output (24) is floating and protected against mismatch of polarity
Actual value voltage:
V
actual value
= 0...10 VDC, depending on the set temp. range, corresponds to:
0...200 °C
0...300 °C
0...400 °C
0...500 °C
0…
nominal
Max. output voltage:
V
actual .value max
= 10.1 VDC
Max. output current:
I
actual value
= 5 mA
Internal resistance:
R
i
= 10
Circuit:
SELV or PELV circuit
Message relay output:
Reed relay contact NO contact message relay (21/29), floating
Max. switching capacity (ohmic load):
10 W
Max. switching voltage:
60 VDC/ 30 VAC
Max. switching current:
0,5 ADC/ 0,35 AAC
Nominal load (ohmic load):
50 V / 100 mA
Lifetime:
electrical
1x10
7
at nominal load
1x10
9
at 5V with 100mA
Supply:
SELV or PELV circuit
Control relay outputs:
Relay change-over contact control relay 1 (16/17/18) and 2 (27/28/29), floating
Max. switching capacity (ohmic load):
2000 VA/ 192 W
Max. switching voltage:
150 VDC/ 250 VAC
Max. switching current:
10 A
Nominal load (ohmic load):
8 A/ 250 VAC
8A/ 24 VDC
Lifetime:
electrical:
100x10
3
with ohmic load
mechanical:
20x10
6
Alarm output:
Reed relay normally open contact (5/6), floating
Max. switching capacity (ohmic load):
10 W
Max. switching voltage:
60 VDC/ 30 VAC