5.2.5. Kalibrierungs-Auswahlmenü
Line 1
C A L . S E L E C T I O N M E N U
Line 2
C a l i b r a t i o n
Line 3
S i n g l e - p o i n t O f f
Line 4
t c c o r r e c t i o n
Line 5
T c c o r r e c t i o n O f f
Line 6
s t o r a g e : O n
Line 7
P - f a c t o r - c o r r e c t i o n
Line 8
V a l u e : 8 8 8 % 3 0 - 2 5 0 %
Press the button
to return to the Working menu (
5.2.1./5.2.2.) without starting a calibration.
Line 1:
Menu name
Line 2:
Select “Calibration” to activate a standard calibra-
tion process of the controller. The Calibration Information
menu (
5.2.5.1.) where the calibration settings are shown
is opened before calibration is started.
Line 3…4:
Option for starting the single-point temperature
coefficient correction; after start of the correction the Work-
ing menu (
5.2.1./5.2.2.) is recalled automatically. The
status of the single-point TC correction is displayed on the
right hand side.
Line 5…6:
Options “Activating and deactivating saving of
the TC correction” for standard and single-point TC correc-
tion.
Line 7:
Name of the following adjustment possibility.
Line 8:
Adjustment of the correction value for the P-factor
correction. When the P-factor correction is deactivated, “Off”
will be displayed instead of a number value. The adjustable
correction range is displayed on the right hand side.
5.2.5.1. Calibration Information menu
Line 1
C A L . - I N F O .
S t a r t
Line 2
T c : A l l o y A 2 0
Line 3
T e m p . r a n g e : 3 0 0 ° C
Line 4
R e f . t e m p . : 2 0 ° C
Line 5
C o m p a r e t i m e : 1 5 s
Line 6
T y p o f C a l . : S a v e
Line 7
T c c o r r e k t i o n : O f f
Line 8
T r a n s f o r m . : E I c o r e
Press the button
to return to the Calibration selection
menu (
5.2.5.) without starting a calibration.
Line 1:
Menu name and “Start” option for starting the cali-
bration. The Working menu (
5.2.1./5.2.2.) is recalled
automatically when starting a calibration.
From the Calibration Information menu you can directly call
up the Settings menus and change the settings before a
calibration.
Line 2:
Menu item and display of the selected temperature
coefficient or material of the heating band (
5.7.1.)
Line 3:
Menu item and display of the selected temperature
range (
5.7.2.)
Line 4:
Menu item and display of the selected reference
temperature for calibration (
5.7.2.)
Line 5:
Menu item and display of the selected calibration
reference time (
5.7.3.)
Line 6:
Menu item and display of the selected calibration
type (
5.7.4.)
Line 7:
Menu item and display whether the standard Tc
correction is used for calibration or not (
5.7.4.)
Line 8:
Menu item and display of the selected transformer
type (
5.7.4.)
5.3. Selection menu
Line 1
S E L E C T I O N M E N U
Line 2
S e q u e n c e c o n t r o l
Line 3
C o n t r o l
Line 4
I n - / O u t p u t
Line 5
C o n t r o l l e r s e t t i n g
Line 6
D i s p l a y s e t t i n g
Line 7
S t o r a g e
Line 8
I n f o r m a t i o n
Press the button
to return to the Working menu (
5.2.1./5.2.2.).
Line 1:
Menu name
Line 2:
Menu item “Sequence control” (
5.4.)
Line 3:
Menu item “Monitoring” (
5.5.)
Line 4:
Menu item “In-/Output setting” (
5.6.)
Line 5:
Menu item “Controller setting” (
5.7.)
Line 6:
Menu item “Display setting” (
5.8.)
Line 7:
Menu item “Storage” (
5.9.)
Line 8:
Menu item “Information menu” (
5.10.)