5.8.2. Hold Mode menu
Line 1
H O L D - M O D E
Line 2
O f f
Line 3
O n
Line 4
2 s O n
Line 5
Line 6
Line 7
Line 8
Press the button
to return to the Display settings menu
(
5.8.).
Line 1:
Menu name
Line 2:
The “Hold mode” option is deactivated
Line 3:
The “Hold mode” option is activated, the last actual
value during the welding process is displayed until the fol-
lowing welding process or welding cycle is started.
Line 4:
The “Hold mode” option is activated, the last actual
value during a welding process is displayed for 2 seconds.
5.8.3. Operating menu
Line 1
C O N T R O L
Line 2
A u t o . t r a n s f e r : O f f
Line 3
O n
Line 4
L o c k i n g : O f f
Line 5
O n
Line 6
M e n u r e t u r n : O f f
Line 7
2 0 s
Line 8
Press the
button to return to the Display settings menu
(
5.8.).
Line 1:
Menu name
Line 2…3:
Options for activating and deactivating the au-
tomatic acceptance of the set numerical values (
4.1.4.).
Line 4…5:
Options for activating and deactivating the lock-
ing of the display unit against unintentional changes of the
settings (
4.1.7.). The locking must be deactivated with
the key combination +
+
Ok
before any settings can be
made. The locking is activated again using the same key
combination.
Line 6…7:
Options for activating and deactivating the au-
tomatic menu return after 20 sec. (
4.1.6.) if no change
was made.
5.8.4. Releases menu
Line 1
R E L E A S E
Line 2
S t a t u s o f
Line 3
r e l e a s e l e v e l 1 :
Line 4
r e l e a s e l e v e l 2 :
Line 5
r e l e a s e l e v e l 3 :
Line 6
Line 7
E n t e r n o . : 8 8 8 8
Line 8
C h a n g e n o . : 8 8 8 8
Press the
button to return to the Display settings menu
(
5.8.).
Line 1:
Menu name
Line 3…5:
Options for the three release levels. When a
lower level is released the levels above are released as
well. The icons on the right hand side
(locked) and
(released) indicate whether the corresponding level and its
settings were released. The cursor jumps automatically in
line 7 for entering the release number after an option was
selected.
Line 7:
Input of the release number to release the selected
release level. The release number is set per digit. Use the
and keys to toggle between the individual digits.
Additional the release level 3 can be activated with the Toss
number as emergency access.
An released release level can be disabled again by entering
the release number "0000" without having to switch off the
controller.
Line 8:
You can only go to Line 8 if the corresponding level
or a higher one was released.
Input of a new release number for the selected release lev-
el. However, the level must have been released before. The
release number is set per digit. Use the
and
keys to
toggle between the individual digits.
Important:
-
After switch off or a reset of the controller
PIREG-D2, all relase levels are locked whose
release number is not "0000".
-
To permanently released a release level, the
release number of this release level must be
set to "0000".
The following settings are assigned to the individual release
levels.
Level 1:
- Target value
- Welding time and cooling time
- Reading parameter sets 1…5