E6582062
8-9
8. Monitoring operation status
3
4
8
9
62
PID result frequency
0.1 Hz
154
Signed speed feedback
frequency (1-second filter)
0.1 Hz
63
PID set value
0.1 Hz
155
Signed torque
1%
64
Light-load high-speed
switching load torque
1%
156
Signed torque command
1%
65
Light-load high-speed torque
during constant speed run
1%
158
Signed torque current
1%
66
Pattern operation group
number
0.1
159
Signed PID feedback value
0.1 Hz
67
Pattern operation remaining
cycle number
1
160
Signed terminal RX input
value
1%
68
Pattern operation preset
speed number
1
161
Signed terminal AI4 input
value
1%
69
Pattern operation remaining
time
0.1
162
Signed terminal AI5 input
value
1%
70
Inverter rated voltage
1 V
*1 Filtered value.
Filter time constant can be set by <F722>.
*2 For details, refer to “RS485 Communication Function Instruction Manual” (E6582143).
Setting
value
Function name
Display unit
Setting
value
Function name
Display
unit