E6582062
11-31
11. Table of parameters
1
3
9
10
11
F592
0592
Shock monitoring
detection
0: Overcurrent/
Overtorque detection
1: Undercurrent/
Undertorque
detection
-
-
0
Y
F593
0593
Shock monitoring
detection level
0 - 250
%
150
Y
F595
0595
Shock monitoring
detection time
0.0 - 10.0
s
0.5
Y
F596
0596
Shock monitoring
detection hysteresis
0 - 100
%
10
Y
F597
0597
Shock monitoring
detection wait time
0.0 - 300.0
s
0.0
Y
F598
0598
Shock monitoring
detection condition
0: During run
1: During run (except
Acc/Dec)
-
-
0
Y
F600
0600
Parameter for
manufacturer
-
-
-
-
-
-
F601
0601
Stall prevention
level 1
10 - 200 (HD)
10 - 160 (ND)
%
150 (HD)
120 (ND)
Y
F602
0602
Trip record retention
0: Clear at power off
1: Retain at power off
-
-
0
Y
F603
0603
Emergency off stop
pattern
0: Trip
1: Trip after Deceleration
stop
2: Trip after Emergency
DC braking
3: Trip after deceleration
stop by F515
4: Trip after Quick
deceleration stop
5: Trip after Dynamic
quick deceleration
stop
-
-
0
N
F604
0604
Emergency DC
braking time
0.0 - 20.0
s
1.0
Y
F605
0605
Output phase loss
detection
0: Disabled
1: At startup (only one
time after power on)
2: At every startup
3: During run
4: At every s
during run
5: Output shut off
detection
-
-
0
N
F606
0606
Motor overload
reduction frequency
threshold
0.0 - 60.0
Hz
6.0
Y
F607
0607
Motor overload time 10 - 2400
s
300
Y
F608
0608
Input phase loss trip
0: Disabled
1: Enabled
-
-
1
N
Title
Communication
No.
Parameter name
Adjustment range
Unit
Minimum
setting unit
(Panel/
Communication)
Default
setting
Write
during
running
*6
User
setting
Reference
Содержание TOSVERT VF-AS3
Страница 2: ...1 9 ...
Страница 14: ......
Страница 17: ...E6582062 iii I 3 9 15 Warranty 15 1 16 Disposal 16 1 ...
Страница 18: ......
Страница 34: ......
Страница 438: ......
Страница 458: ......
Страница 470: ......
Страница 482: ......
Страница 502: ......
Страница 572: ......
Страница 590: ......
Страница 608: ......
Страница 616: ......
Страница 618: ......
Страница 620: ......
Страница 621: ...1 3 9 10 ...