6. [Advanced] How to use parameters
3
4
6
9
6. 2. 2
Selecting input voltage of the terminal [RX]
<F107: Terminal RX input voltage select>
■
Function
This parameter selects the input voltage of the terminal [RX].
■
Parameter setting
■
Difference between the settings
0: 0 to +10 V
Input 0 to 10 Vdc between the terminals [RX]-[CC].
The resolution is 1/1000 at the maximum at 0 to 10 Vdc.
1: -10 to +10 V
Input -10 to +10 Vdc between the terminals [RX]-[CC].
The resolution is 1/2000 at the maximum at -10 to +10 Vdc.
Title
Parameter name
Adjustment range
Default setting
F107
Terminal RX input
voltage select
0: 0 to +10 V
1: -10 to +10 V
0
Reference
• How to operate the operation panel -> Refer to [3. 1. 1].
• How to switch display mode on the operation panel -> Refer to [3. 1. 2].
• Procedure to change parameter setting -> Refer to [4. 2. 3]
• Details on operation by external signals -> Refer to [Chapter 7].
0: 0 to +10V
1: -10
〜
+10V
0.0Hz
STOP
12:45
F107 : Terminal RX input voltage select