E6582062
4. [Basic operation] Operation methods of motor
4-20
4
9
This section introduces panel run methods with basic examples.
Input a run command and a frequency command from the operation panel.
4. 3. 1
[Operation example 1] Operating with [RUN] key/
[STOP] key on operation panel
Operate only with the operation panel.
• First, make setting so that a run command and a frequency command can be input from the operation
panel.
• Then, set a frequency command on the operation panel. The motor will rotate with this frequency.
• After setting the above, operate by using the keys on the operation panel.
• The parameters to be set are <CMOd: Run command select> and <FMOd: Frequency command
select 1>.
1
To set parameters, switch to [Setting mode].
Select "4. Basic parameter" and press the [OK]
key. The basic parameter screen is displayed.
2
Select <CMOd: Run command select> and press
the [OK] key.
You can also select <CMOd: Run command
select> on the [Easy mode] screen.
4. 3
Basic panel run methods
Reference
• How to switch the display mode of the operation panel -> Refer to [3. 1. 2]
• Procedure to change parameter setting -> Refer to [4. 2. 3]
• Details of <CMOd: Run command select>, and <FMOd: Frequency command select 1> ->
Refer to [5. 2]
1.
History function
2.
Direct access
3.
Guidance function
4.
Basic parameters
5.
Extended parameters(F - - -)
Top
0.0Hz
STOP
15:13
Monitor
Setting Mode
0.0Hz
STOP
15:14
Basic parameters
CMOd
: Run command select
FMOd
: Frequency command select 1
vb
: Manual torque boost 1
vL
: Base frequency 1
0
1
4.80%
60.0Hz
Pt
: V/f Pattern
0
Содержание TOSVERT VF-AS3
Страница 2: ...1 9 ...
Страница 14: ......
Страница 17: ...E6582062 iii I 3 9 15 Warranty 15 1 16 Disposal 16 1 ...
Страница 18: ......
Страница 34: ......
Страница 438: ......
Страница 458: ......
Страница 470: ......
Страница 482: ......
Страница 502: ......
Страница 572: ......
Страница 590: ......
Страница 608: ......
Страница 616: ......
Страница 618: ......
Страница 620: ......
Страница 621: ...1 3 9 10 ...