6. [Advanced] How to use parameters
3
4
6
9
Various signals are input to the inverter for motor operation.
For details on the input terminal function, refer to [7. 2. 1].
6. 2. 1
Selecting operation at simultaneous input of Fwd/
Rev commands
<F105: Fwd/Rev priority of both close>
■
Function
This parameter selects operation performed (reverse run or deceleration stop) when the Fwd and
Rev signals are simultaneously input.
■
Parameter setting
■
Difference between the settings
0: Reverse
When the Fwd and Rev signals are simultaneously input, reverse run is performed.
6. 2
Input signals to the control terminals
Title
Parameter name
Adjustment range
Default setting
F105
Fwd/Rev priority of both
close
0: Reverse
1: Stop
1
0: Reverse
1: Stop
0.0Hz
STOP
12:45
F105 : Fwd/Rev priority
Frequency command value
Frequency command value
ON
OFF
ON
OFF
Output frequency (Hz)
Time (s)
Terminal [F]
(Fwd run)
Fwd
Rev
Terminal [R]
(Rev run)
0