GTCOM2
Installation & Programming Manual
GSM SMS/DIAL Communicator Contact ID to GSM SMS Message Text Converter
This manual includes steps to install, set up and use your system.
Made in the European Union
Страница 1: ...GTCOM2 Installation Programming Manual GSM SMS DIAL Communicator Contact ID to GSM SMS Message Text Converter This manual includes steps to install set up and use your system Made in the European Union ...
Страница 2: ... or via USB using SERA2 upload download software Features of the module GTCOM2 Connects to panel s landline dialer Communicator can be connected to control panel s landline dialer with 2 or 4 wires When connected with 4 wires the landline between the panel and communicator will be monitored Sends events to monitoring station receiver Can send event messages to SIA DC 09 receivers Connection superv...
Страница 3: ...heating cooling control 29 4 Configuration methods 30 4 1 System Access codes 30 4 1 1 App Key 31 4 1 2 Installer and User passwords 31 4 1 3 Master code for access control via keypad 32 5 Programming 32 5 1 SERA2 Uploading Downloading Software 32 6 Reporting to the Central Monitoring Station 33 6 1 GPRS IP TCP UDP details programming 33 6 2 Central Monitoring Station details programming 33 6 3 Ge...
Страница 4: ... about alarmed sensors Door PIR Fire etc SMS message is being sent to a user in line with a short call This is to reduce the probability that a user will not observe SMS message It is possible to send SMS and to call to 8 users The algorithm of message sending is SMS1 SMS2 SMSn till all SMS messages will be send After DIAL1 DIAL2 DIALn It is possible to send alarm events to the monitoring station ...
Страница 5: ...evices instantly configure necessary options for example enabling disabling PGM outputs etc Event The information that the user receives Event Log A list of system events that is uploaded from the device s memory to the configuration software for further analysis The system logs all information about system configuration system actions and info messages iButton key A unique 64 bit ID code containi...
Страница 6: ...i USB cable Humidity sensor AM2305 Water Proof DS18b20 Temperature Probe with 1m cable Temperature sensor DS18B20 Humidity sensor AM2320 Humidity sensor DHT22 AM2302 1 5 General view of the module Do not locate SIM card with force because you may damage SIM card holder 1 6 Meaning of LEDs and contacts Table 3 Meaning of LEDs Name Indication variations Meaning REG yellow built in LED Lights continu...
Страница 7: ...eceived correctly Figure 2Meaning of leds LINE blue LED lights continuously when central panel OFF HOOK DTMF LED is blinking 5 10ms When DTMF LED lights for 1s data received correctly Table 4 Terminal block Contacts Contact No Name Max voltage V Optional functions and Description 1 DC 24 DC 10 16V Max 0 2A 2 COM Common terminal negative 3 TIP Terminal to connect with security control panel TIP ter...
Страница 8: ...that you have the necessary 1 USB cable Mini B type for configuration 2 At least 4 wire cable for connecting communicator to control panel 3 Flat head 2 5mm screwdriver 4 Sufficient gain cellular antenna if network coverage in the area is poor 5 Activated Nano SIM card PIN code request can be turned off 6 Particular security control panel s installation manual Order the necessary components separa...
Страница 9: ...mming manual provides the basic installation wiring and programming information required to program the module GTCOM2 and connect all third party devices to the module Communication wiring methods Programming the control panel Programming GTCOM2 communicator Error Reference source not found Reporting to the Central Monitoring Station 3 1 Communicator wiring methods Figure 6 Remove the top lid Figu...
Страница 10: ...ones pre configured as a keyswitch If the control panel status changes from ARM to DISARM the status of GTCOM2 changes from ARM to DISARM also If the siren is triggered the SMS will be send to the user s mobile followed by a call GTCOM2 could be used for all control panel control gate control The second keyswitch can be used to stay ARM The first keyswitch could be used for arm the first partition...
Страница 11: ...phone number Telephone number e g 1234 o Set communication dialing options to DTMF Dialing o Set Communications protocol to DTMF Contact ID o If panel has such option set Contact ID Automatic Reporting Codes o Enable PSTN communication events upon your needs Open Close Alarm Restore Maintenance Test Panel s settings for two ways ARM DISARM synchronization APP Call SMS iButton GTCOM PANEL Panel Key...
Страница 12: ...s lt website Go to Device GTCOM2 in the command line Figure 13 Sera2 PROGATE Outputs and Sera2 PROGATE Inputs Burglar Alarm Zones windows Stay and Sleep modes could be used as keyswithes Call to the module You will receive SMS Your phone number will be saved Enter your phone number in GSM Communication window Edit settings Press Write Control primary panel from GTCOM2 and see the status in app rec...
Страница 13: ...or Ademco Contact ID codes into SMS text GTCOM2 communicator simulates operation of dial up line and received Contact ID messages from the security control panel All information from the security control panel to the module is being transferred in DTMF tones The security control panel must support tone DTMF dialing Also data transfer CONTACT ID protocol in DTMF tones Pulse format is not available ...
Страница 14: ... code GG partition CCC zone user number CONTACT ID messages are described in Sera2 PSTN CID to SMS converter window in 3 tables XYZ GG CCC Event description text may be changed Thus desirable text may be generated for every received CONTACT ID message Step by Step 1 Go to Sera2 GSM Communication SMS DIAL reporting Enter phone numbers mark events and edit settings 2 Go to Sera2 PSTN CID to SMS Conv...
Страница 15: ...ndow Figure 15Users Access control window Arm Disarm by mobile web app Tap the ARM ARM Stay ARM Sleep DISARM in the mobile web app System window Arm Disarm by call It is possible to arm disarm the system and turn OFF the alarm by dialing the system s phone number from any of 800 available user phone numbers The system ignores any incoming calls from a non listed phone number The phone call is free...
Страница 16: ...s Arm Disarm by RFID key card keyfob To arm disarm the system with RFID keycard touch 1 of 800 RFID keycard to the Wiegand keypad When the RFID keycard is touched to the reader for arming disarming the system will proceed arming disarming process Refer to Users Access Control programming details And Refer to DISARM ARM SLEEP STAY the security system 3 3 4 Wiegand Keypad RFID Card Reader iButton Pr...
Страница 17: ...s Digital I O settings Set Digital I O D2 to Wiegand Interface DATA0 Set Digital I O D3 to Wiegand Interface DATA1 Press Write Go to Sera2 System Options General system Options Press Start iButton RFID Phone programming mode Go to Sera2 Users Access control window Touch RFID keycards to the reader RFID keycard number will appear in the list Go to System Options General system Options and Press Sto...
Страница 18: ...et Digital I O D3 to Wiegand Interface DATA1 Press Write Go to Sera2 Users Access control Enter RFID keycard number Edit other settings Press Write Go to RT Testing Monitoring Hardware Press Start Monitoring Go to Security Alarm Panel Access Touch the keycard to the RFID keypad Start automatic learning mode remotely via Sera2 software Start Sera2 software Press Connect remotely button Enter requir...
Страница 19: ... cycle will repeat until output is deactivated Output signal Pulse time ON Pulse time OFF Pulse time ON Pulse time OFF Output state Output ON Output OFF Bell Output for connection of audible sounder siren After the alarm system actuation a continuous or pulse fire signal is generated OFF ON Alarm Bell time Bell ARM DISARM Output for connection of light indicator of the alarm system status When the...
Страница 20: ... generated when communication with secondary channel was lost OFF ON Lost Secondary Channel Lost Secondary Channel Restore Primary Channel 3 4 1 Output PGM wiring Bell Relay Led Wiring Output switch to ground when activated from the module Connect the positive side of the device to be activated to the VD terminal Connect the negative terminal to the selected output 1 Connect devices to the selecte...
Страница 21: ...nes with selectable type NC NO EOL EOL TAMPER 2 programmable analog inputs I O1 I O2 0 30V for analog sensors control or using as security system s zone with selectable type NC NO EOL EOL TAMPER Wiegand interface RFID reader Keyboard 1 programmable digital inputs D1 Max voltage 3 3V used for o Dallas 1 Wire Bus To connect temperature sensors DS18b20 or iButton key DS1990A o Aosong 1 Wire bus Humid...
Страница 22: ...Steps to start AM2320 and AM2302 sensors 1 Connect AM2320 or AM2302 to the Digital I O D1 according connection diagram Figure 25AM2320 connecting diagram Figure 26 AM2302 connecting diagram 2 Sensor s type should be select in the Sera2 System Options General System Options window Set Digital I O D1to Aosong 1 Wire bus Humidity Temperature Sensor AM2302 Figure 27 System Options General System Optio...
Страница 23: ...nts list 7 Real time hardware status RT Testing Monitoring Hardware Press Start Monitoring 8 The list of alarm events with time and date stamp RT Testing Monitoring Event Monitoring 9 It is possible to receive alarm SMS to the mobile phone GSM Communication SMS Dial reporting 10 Real time sensor values and states RT Testing Monitoring Sensors Automation 3 5 2 Analog inputs 0 30V Steps to start ana...
Страница 24: ...erature measurements The DS18B20 communicates over a 1 Wire Each DS18B20 has a unique 64 bit serial code which allows multiple DS18B20s to function on the same 1 Wire bus Thus it is simple to use one to control many DS18B20s distributed over a large area Applications that can benefit from this feature include HVAC environmental controls temperature monitoring systems inside buildings equipment or ...
Страница 25: ...onnection diagram Figure 36DS18b20 connection with long distance UTP or FTP cable 2 If you need to connect more sensors to the same input connect them as a star or serial Each line should be separated by 82 120 Ohm resistor Figure 37 Star connection The resistor must be as close as possible to the contacts of the module GTM1 ...
Страница 26: ...es in the data line of each sensor before connecting to the network The total length of the bus from 10 to 100m Depending of cable quality sensors number on bus and environment noise There is possibility to connect up to 32 devices Begin the installation by mounting additional devices in the cabinet using the stand offs provided then mount the cabinet in a dry protected area with access to unstitc...
Страница 27: ...ve alarms and where find alarm events list Real time hardware status RT Testing Monitoring Hardware Press Start Monitoring The list of alarm events with time and date stamp RT Testing Monitoring Event Monitoring It is possible to receive alarm SMS to the mobile phone GSM Communication SMS Dial reporting Real time sensor values and states RT Testing Monitoring Sensors Automation Refer to RT Testing...
Страница 28: ...nges at home Min Value Alarm temperature can prevent the pipes from freezing even if the heating system is broken The module GTM1 will inform the user send alarm SMS and call Temperature control system relies upon a controller which accepts a temperature sensor as input It compares the actual temperature to the desired control temperature or set point and provides an output to a control element An...
Страница 29: ...is is created between the ON and OFF operations In cases where this cycling occurs rapidly and to prevent damage to contactors and valves an on off differential or hysteresis is added to the controller operations This differential requires that the temperature exceed set point by a certain amount before the output will turn off or on again Figure 43 The example of configuration Sera2 Automation Se...
Страница 30: ... topkodas lt Downloads GTalarm2_TPS12_AN_EN pdf 4 Configuration methods SMS text messages In order to configure and control the device by SMS text message send the text command to the GTCOM2 device number from one of the listed administrator phone numbers Sera2 software Configuration by USB cable and Sera2 software does not require the external power supply to be connected to the device However th...
Страница 31: ...ns General system options User Access Code Format Control functions for all newly associated keys will be assigned according to MASTER key For example If MASTER key will control Out1 all newly associated keys will also control Out1 4 1 1 App Key 1 Change default App Key Default 123456 Sera2 GSM Communication Sera Cloud Service 2 Enter App Key for the remote connection via Sera2 Go to Sera2 Setting...
Страница 32: ...ion of the software SERA2 Click the file SERA2 setup exe 2 If installation directory of the software is OK press Next If you would like to install the software in the other directory press Change specify other installation directory and then press next 3 Check if the correct data are entered and press Install 4 After successful installation of the software SERA2 press Finish Start the software SER...
Страница 33: ...Update in the bottom line in SERA2 software If you want to update the module manually got to About and press Check for updates If you need to contact the seller with the questions about the configuration you have to Press Read icon first to read the configuration from the module the press File Save us and save the configuration Save the Events Log file and send these files with the question to the...
Страница 34: ...NO data will be queued up and all data messages will be lost Phone calls via GSM network to the listed user phone number in case of alarm are disabled by force when MS mode is enabled Data Messages Events The system supports the following communication methods and protocols GPRS network SIA IP protocol ANSI SIA DC 09 2012 configurable as encrypted and non encrypted SMS SMS to User text format Init...
Страница 35: ...a IP connection the date and time will be automatically synchronized with the monitoring station It is possible to select automatically time synchronization with GSM Modem Cloud Server or disable it Figure 57 Clock time Zone and clock synchronization Sera2 System Options General System Options If the module has been connected first time to the power supply or power supply has been disconnected for...
Страница 36: ...GTCOM2 User manual 36 E N Figure 58 System Options General System Options Figure 59 System Options General system options window 6 4 Users Access Control programming details ...
Страница 37: ...be controlled only by these users whose phone numbers entered in the memory of the module Figure 60 Users Access control window The module GTCOM2 controls access by using schedules Inputs outputs readers and cards through access levels are all configured with schedules by which they will be energized or de energized enabled or disabled For example you might assign an output to be energized from 12...
Страница 38: ...es as follows 2 Monday Friday 5 p m 11 59 p m Remember the time range cannot cross midnight so 11 59 p m is the limit 3 Tuesday Saturday 12 00 a m 1 00 a m 4 Saturday Sunday 8 00 a m 1 00 p m Note Holidays should be considered special days of a week They are similar but of higher rank than the standard Monday Sunday If a day programmed as a Holiday should occur in the panel the panel will treat th...
Страница 39: ...ss is granted by user 421 event Access granted is stored into the log If not Access denied event 422 is stored to the log Sera2 Events Log if output will have definition Automation CTRL it also can be controlled by user in any way but it will not generate 421 and 422 events Event log e g 1853 Event 1234 1 401 01 001 Time 2017 08 20 14 42 36 Note Open by User User 001 Name Master 1852 Event 1234 1 ...
Страница 40: ...GTCOM2 User manual 40 E N Figure 65 Outputs PGM window 6 6 DISARM ARM SLEEP STAY the security system System Options System Fault Troubles In this window System trouble settings could be configured ...
Страница 41: ...rouble the arming activation will be restricted The system supports up to 800 user phone numbers for remote control purpose When the phone number is set the user will be able to arm disarm the system and control outputs by SMS text messages and free of charge phone calls as well as to configure the system by SMS text messages By default the system accepts incoming calls and SMS text messages from ...
Страница 42: ...remote system configuration ability via Internet using TCP IP server on SERA2 software The connection can be established on the system via GPRS network After the remote system configuration is complete the session will automatically expire in 20 minutes Alternatively the connection with the server can be terminated at any time by sending an SMS text message NEVER add a phone number of the device s...
Страница 43: ...y times as programmed and the same order as phone numbers listed in the memory if it end up with all unsuccessful attempts to dial to the user The module could be controlled and monitored only by these users whose phone numbers entered in the memory of the module Figure 69 GSM Communication SMS DIAL reporting 6 7 2 Custom SMS Text GSM Communication Custom SMS Text The Custom SMS Text options let y...
Страница 44: ... settings and enable or disable remote communication Figure 72 GSM Communication SERA Cloud Service window 6 10 Events Log Events Log The Event Log window show real time information of the events that has been occurred The event log allows to chronologically register up to 2048 time stamped records regarding the following system events System start System arming disarming Zone violated restored Ta...
Страница 45: ...ote location to a central office A user can access this data anytime anywhere Testing Monitoring You need to monitor the temperature humidity maybe even the security Localized Monitoring Systems Perfect for many applications SeraServer technology can be used in labs clean rooms museums warehouses computer rooms food processing storage hospitals and greenhouses as well as HVAC pharmaceutical electr...
Страница 46: ...Digital input type D1 D2 D3 should be select in the System Options Digital I O Settings window Set digital input definition D1 D2 D3 to Dallas 1 Wire Bus option Figure 75System Option General System Options window 8 Write configuration by pressing Write icon Figure 76Command line 9 Power the module 10 After module starts Within few seconds it will automatically scans and registers all connected 1 ...
Страница 47: ...tion of every field in Automation Sensors window 26 X multiplier Mult Coef Correction X multiplier coefficient Following the equation Temperature X ADC Y to calculate X and Y coefficients Measure temperature in two points at least 27 Y offset Sum Coef Correction Y offset coefficient Following the equation Temperature X ADC Y to calculate X and Y coefficients Measure temperature in two points at le...
Страница 48: ...ng Event Monitoring It is possible to receive alarm SMS to the mobile phone GSM Communication SMS Dial reporting Real time sensor values and states RT Testing Monitoring Sensors Automation Figure 79 How to check real time hardware status real time sensor values How to receive alarms and where find alarm events list Refer to RT Testing Monitoring Hardware Refer to Real time Testing Monitoring Event...
Страница 49: ...ware monitoring window let you see real time input output actions and GSM information Thus it would be easier to evaluate whether the input output actions registration to the network operates as appropriate Figure 80 RT Testing Monitoring Hardware window Figure 81 RT Testing Monitoring Hardware window ...
Страница 50: ...2 2 Real time Testing Monitoring Event Monitoring RT Testing Monitoring Event Monitoring The Event Monitoring window will show real time events information Figure 83 RT Testing Monitoring Event Monitoring window 6 13 RT Testing Monitoring Security Alarm Panel Access RT Testing Monitoring Security Alarm Panel Access The Security Alarm Panel Access window let you see real time zones states is zone a...
Страница 51: ...ule over the internet The system parameters may be changed Monitoring system status temperature sensors may be observed Firmware update of the module How does it works Remote connection is established via GPRS using TCP IP protocol The GSM module connects to the internet via a GPRS to SERA cloud server cloud topkodas lt The connection is established by the SERA2 configuration tool using unique ID ...
Страница 52: ...ssing Write icon Figure 86 GSM Communication Sera Cloud Service window 6 Go to Sera2 GSM Communication CMS Reporting Figure 87GSM Communication CMS Reporting window 7 Public IP or domain must be entered Enter remote port ping time encryption key and enable the communication 8 If needed APN Password Login IP Domain Port PING time KEY can be set by SMS commands GPRS network settings INST000000 008 A...
Страница 53: ...d notification SERA2 software can remember all IMEI that was entered in the past If needed to clean the list UID IMEI press Clear History 7 Info Hardware Firmware Bootloader Serial No Updates System Options System Info The System Info window let you take a look to the main hardware boot loader firmware serial no IMEI GSM Modem information Figure 89 System Options System Info window 7 1 Firmware Up...
Страница 54: ...1 https cloud topkodas lt index php Settings and GSM Communications Sera Cloud Service windows App key in module and APP must be the same IMEI device UID you can find on the modem of the module or in SERA program System Options System info Figure 92System Options System Info window ...
Страница 55: ...ace character Second configuration array etc Identification USER User used for module s control Installer s or user s password space character Command code space character First configuration array space character Second configuration array etc 10 The table of installers commands SMS commands with correct INST password can be send from any phone number Keep INST password in secret SMS configuratio...
Страница 56: ...INST000000 009 ADDR PORT PING SERA cloud Service Parameters 009 command code Remote control of the module over the Internet ADDR the format of IP address xxx xxx xxx xxx the numbers from 0 to 255 should be separated by dot or domain text length of up to 47 characters PORT TCP port number from 1 to 65535 Default parameters is in the picture bellow We recommend do not change these parameters INST000...
Страница 57: ...ged before exploitation of the module 090 command code Change of installer s password NEW_INST_PSW New Installer s password INST000000 091 NEW_USER_PSW Change user s password User s password should be changed before exploitation of the module 091 command code Change user s password NEW_USER_PSW New user s password INST000000 092 Remote reset of the module via SMS messages 092 command code Remote r...
Страница 58: ...from 1 to 10 ST output mode 0 deactivated output 1 activated output USER123456 022 N TIME Output activation for the time interval 022 command code Output activation for the time interval N output number 1 10 TIME 0 999999 Time interval in seconds for the output activation USER123456 030 ST Change security system s mode ARM DISARM STAY SLEEP 030 command code Change security system s mode ARM DISARM...
Страница 59: ... use It does not cover Damage incurred in shipping or handling Damage caused by disaster such as fire flood wind earthquake or lightning Damage due to causes beyond the control of UAB Topkodas such as excessive voltage mechanical shock or water damage Damage caused by unauthorized attachment alterations modifications or foreign objects Damage caused by peripherals unless such peripherals were supp...
Страница 60: ... or building Every fire is different in the amount of smoke produced and the rate of burning Smoke detectors cannot sense all types of fire is equally well Smoke detectors may not provide timely warning of fires caused by carelessness or safety hazards such as smoking in bed violent explosions escaping gas and improper storage of flammable materials overloaded electrical circuits and children play...