17
■
RS-232C specification
Parameters other than Baud rate and Delimiter are invariable.
・
Communication method
:Full duplex
・
Synch method
:Start-stop transmission
・
Baud rate
:9600/19200/38400 bps
(
Bits Per second
)
・
Data length
:7 bit
・
Parity
:ODD
・
Stop bit
:
1
bit
・
Communication format
:Text
(
ASCII
)
・
Delimiter
:”CR+LF” or “CR” is appended to the end of the
communication data row
■
LAN
(
TCP/IP
)
specification
・
Ethernet 10 /100 Base-TX
When connect PC, set following parameter in the function mode.
・
LAN communication parameter setting
Refer to
☞
「
3.2.6 LAN Parameter
」
・
RS-232C communication parameter setting
Refer to
☞
「
3.2.7 RS-232C Parameter
」
■
Object collimation
Do not look at directly bright light such as the Sun and the filament lamp,
otherwise it cause damage to eye.
Request
Use only specified screws when using the tripod screw and screw holes for
jig attachment. Do not tighten the screws any more than necessary. Doing so
might cause internal breakage.
1
Fix the instrument to stand such as tripod.
2
Remove the objective lens cap.
3
Open the finder shutter.
4
Look into the eyepiece and turn the diopter adjustment ring to focus on the reticle Mark.
5
Collimate with the object and turn the focus ring of objective lens to focus on the object.
Reticle Mark
Prohibited