Contents
Thermo Scientific
42iQHL Instruction Manual
v
Compression ................................................................................. 4-2
Drying .......................................................................................... 4-2
Oxidation ...................................................................................... 4-2
Scrubbing ...................................................................................... 4-3
Gas Phase Titrator............................................................................ 4-3
Flow Controllers ........................................................................... 4-3
Pressure Regulator ......................................................................... 4-3
Ozone Generator .......................................................................... 4-4
Diverter Valve ............................................................................... 4-4
Reaction Chamber ........................................................................ 4-4
Mixing Chamber ........................................................................... 4-4
Output Manifold .......................................................................... 4-5
Reagents ........................................................................................... 4-5
NO Concentration Standard ......................................................... 4-5
Assaying a Working NO Standard Against a NIST-traceable NO
Standard ........................................................................................ 4-5
Zero Air ........................................................................................ 4-6
Dynamic Parameter Specifications for Gas Titrator .......................... 4-6
Determining GPT System Flow Conditions ................................. 4-7
Pre-Calibration ................................................................................... 4-8
Calibration .......................................................................................... 4-9
Connect GPT Apparatus to the Analyzer ....................................... 4-10
Adjust Instrument Gain ................................................................. 4-10
Set NO and NO
x
Backgrounds to Zero ....................................... 4-10
Calibrate the NO Channel to the NO Calibration Gas ............... 4-12
Calibrate the NO
x
Channel to the NO
x
Calibration Gas ............. 4-12
Preparing NO, NO
x
, and NO
2
Calibration Curves ..................... 4-13
Calibration in Dual Range and Auto Range Mode ............................ 4-16
Set NO and NO
x
Background to Zero ........................................... 4-16
Calibrate NO Low ......................................................................... 4-17
Calibrate NO
x
Low ......................................................................... 4-17
Calibrate NO
2
Low ........................................................................ 4-18
Calibrate NO High ........................................................................ 4-18
Calibrate NO
x
High ....................................................................... 4-19
Calibrate NO
2
High ....................................................................... 4-19
Zero and Span Check ........................................................................ 4-20
Manual Calibration ........................................................................... 4-21
Adjust NO and NO
x
Backgrounds ................................................. 4-22
Adjust Span Coefficient.................................................................. 4-23
Reset Bkg to 0.000 and Span Coef to 1.000 ................................... 4-23
Zero/Span Schedule .......................................................................... 4-24
Next Time ..................................................................................... 4-24
Period ............................................................................................ 4-24
Zero/Span/Purge Duration Minutes .............................................. 4-25
Schedule Averaging Time ............................................................... 4-25
Background Calibration and Span Calibration ............................... 4-25
Содержание 42iQHL
Страница 1: ...42iQHL Instruction Manual High Level NO NO2 NOx Analyzer 119018 00 27Sep2018 ...
Страница 2: ......
Страница 18: ......
Страница 28: ......
Страница 36: ...Operation Instrument Display 3 8 42iQHL Instruction Manual Thermo Scientific ...
Страница 98: ...Operation Settings 3 70 42iQHL Instruction Manual Thermo Scientific Digital I O Digital I O serial number ...
Страница 100: ...Operation Settings 3 72 42iQHL Instruction Manual Thermo Scientific Sample Valve Zero Valve Span Valve Bypass Pump ...
Страница 166: ......
Страница 192: ......
Страница 198: ...Maintenance Pump Rebuilding 5 6 42iQHL Instruction Manual Thermo Scientific Figure 5 2 Pump Rebuilding ...
Страница 214: ...Servicing Fan Replacement 7 8 42iQHL Instruction Manual Thermo Scientific Figure 7 8 Replacing the Fan ...
Страница 257: ...Servicing DMC Ozonator Thermo Scientific 42iQHL Instruction Manual 7 51 Figure 7 52 Remove Ammonia Scrubber ...
Страница 272: ......
Страница 308: ......
Страница 320: ......
Страница 321: ......