9 Appendix
104
annual check of the testo 350 by Testo Service is
recommended.
Cross-sensitivities
This table is valid for new sensors with possibly unused filters, and
for cross-gas concentrations in the ppm-range (down to less than
1000ppm).
The value "0" means: <1% cross-sensitivity.
Target gas
Cross-gas
CO
NO
SO
2
NO
2
H
2
S
O
2
0
0
0
0
CO(H
2
)
---
0
0
CO(H
2
)
low
---
0
NO
0
---
(w)
0
NO
low
0
---
<5%
0
NO
2
0
0
<-2%
---
-20%
SO
2
<5%
0
---
-110%
SO
2 low
<5%
0
---
-110%
CxHy
0
H
2
S
<2%
<15%
<20%
-20%
---
Target gas
Cross-gas
H
2
Cl
2
HCI
HCN
CO
2
O
2
0
0
0
0
see
10
With non-saturated filter.
11
w = changeable filter
12
Is compensated, if the cross-gas in the instrument is also measured
(i.e. if the instrument is equipped with the corresponding sensors).
13
No influence up to a few 1000ppm; for cross-concentrations in the
%-range 0.3% O
2
per 1% SO
2
/ HCl.
14
0.3% O
2
per 1% CO
2
; is compensated