![Tektronix 80A00 Скачать руководство пользователя страница 90](http://html1.mh-extra.com/html/tektronix/80a00/80a00_technical-reference_1077946090.webp)
Performance Tests
80C08D performance test
Minimum
Incoming
Outgoing
Maximum
11197.5
–6.37
–8.75
–3.99
12796.9
–8.54
–11.53
–5.56
14396.7
–10.93
–14.45
–7.41
15996.5
–13.41
–17.41
–9.41
FEC 10.71Gb/s Reference Receiver Setting Frequency Response (G.709)
Frequency (MHz)
Nominal response (dB)
0.00
0.00
–0.85
+0.85
1606.6
–0.11
–0.96
+0.74
3212.8
–0.45
–1.30
+0.40
4819.0
–1.02
–1.87
–0.17
6426.0
–1.86
–2.71
–1.01
8032.0
–3.00
–3.86
–2.16
9638.4
–4.51
–6.19
–2.83
10709.2
–5.71
–7.87
–3.55
11245.0
–6.37
–8.75
–3.99
12851.1
–8.54
–11.53
–5.56
14457.7
–10.93
–14.45
–7.41
16064.4
–13.41
–17.41
–9.41
10.66 Gb/s Data Filter frequency response (dB)
Frequency (MHz)
Nominal response (dB)
0.00
0.00
–0.85
+0.85
1500
–0.11
–0.96
+0.74
3000
–0.45
–1.30
+0.40
4500
–1.02
–1.87
–0.17
6000
–1.86
–2.71
–1.01
7500
–3.00
–3.86
–2.16
9000
–4.51
–6.19
–2.83
10000
–5.71
–7.87
–3.55
10500
–6.37
–8.75
–3.99
12000
–8.54
–11.53
–5.56
13500
–10.93
–14.45
–7.41
15000
–13.41
–17.41
–9.41
10.709 Gb/s Data Filter frequency response (dB)
Frequency (MHz)
Nominal response (dB)
0.00
0.00
–0.85
+0.85
1500
–0.11
–0.96
+0.74
3000
–0.45
–1.30
+0.40
4500
–1.02
–1.87
–0.17
72
DSA8300 Performance Veri
fi
cation
Содержание 80A00
Страница 2: ......
Страница 6: ......
Страница 16: ...Important safety information x DSA8300 Performance Verification ...
Страница 213: ...Electrical Sampling Modules Figure 21 Setup to measure Power in DSA8300 Performance Verification 195 ...