Chapter 4 Software index
4-24
F50 Low frequency voltage compensation, C14=000
Performance: During low frequency
Increase F50 setting value can increase output voltage and low frequency torque.
Decrease F50 setting value can decrease output voltage and low frequency torque.
• Output voltage/frequency curve pattern:
• Operating frequency range:
• During low frequency use:
When the motor output torque is not enough and increase F50 setting value.
When the motor is vibration and decrease F50 setting value.
F51 Advanced parameter
function display
000:Disable access to advanced parameters ( Group C )
001:Enable access to advanced parameters ( Group C )
F51=000. Parameter group C can not be displayed or accessed.
F51=001. Enable display and access parameter group C .
F52 Factory default
010: Reset parameters to factory default (50Hz)
020: Reset parameters to factory default (60Hz)
F53 Software version
F54 Fault records (Latest 3 times)
Advanced Parameters List ( Group C parameters)
C00 Reverse run
000: Reverse enable
001: Reverse disable
F04=000 and C00=001, F03 (motor direction) disable, the inverter is set to forward operation.
F04=001 or 002, and C00=001, reverse command is disable.
F50
V
F
0~12HZ / 60HZ
0~10HZ / 50HZ
Содержание 7300EV
Страница 14: ...Chapter 3 Environment description and installation 3 4 z EV 1P2 1P5 101 2P2 2P5 201 N4S install TM1 TM2 ...
Страница 15: ...Chapter 3 Environment description and installation 3 5 z EV 1P2 1P5 101 2P2 2P5 201 N4 install TM1 TM2 ...
Страница 86: ...Chapter 6 Peripherals 6 4 z JNFS21015 22 07 FOR EV 202 203 H1 z JNFS21016 15 07 FOR EV 202 203 H3 ...
Страница 87: ...Chapter 6 Peripherals 6 5 z JNFS20858 7 07 FOR EV 401 403 H3 ...