Chapter 4 Software index
4-11
2.) F5=002,when one of parameter group F11~ F15 is set to 015 and multi-function input terminal
is OFF, the frequency is set by analog signal (auxiliary speed) from TM2. If the multi-function
input terminal ON, the frequency is set by VR on Keypad.
3.) Up/Down terminal: please refer to description of parameter group F11~ F15(multi-function
input terminal).
4.) Priority of reading frequency command: Jog> preset frequency > (Keypad
Ÿź
or TM2 UP/
Down or communication)
F06 : External control operation mode
000: Forward/ Stop-Reverse/Stop
001: Run/ Stop-Forward/Reverse
002: 3-wire—Run/ Stop
1.) F06 is only available when When F04 = 001 (external terminal).
2.) When both forward and reverse commands are ON, it will be take into Stop.
※
•
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••••
~
•••••••••••••••••••••
(1). NPN input signal:
S1 (
Forward/Stop
)
S2 (
Reverse/Stop
)
COM
( Common)
(2). PNP input signal:
Parameter F06 = 001, Control method is as following:
(1). NPN input signal:
S1 (
Run/Stop
)
S2 (
Forward
/
Reverse
)
COM
( Common)
(2). PNP input signal:
S1 (
Run/Stop
)
S2 (
Forward
/
Reverse
)
24V
( Common)
Parameter F06 = 002, Control method is as following:
(1). NPN input signal:
(2). PNP input signal:
S1 (
Run
)
S2 (
Stop
)
S3 (
Forward/ reverse
)
COM ( Common)
S1 (
Run
)
S2 (
Stop
)
S3 (
Forward/ Reverse
)
24V
(Common
)
S1 (
Forward/Stop
)
S2 (
Reverse/Stop
)
24V
( Common)
Parameter F06 = 000, Control method is as following:
Содержание 7300EV
Страница 14: ...Chapter 3 Environment description and installation 3 4 z EV 1P2 1P5 101 2P2 2P5 201 N4S install TM1 TM2 ...
Страница 15: ...Chapter 3 Environment description and installation 3 5 z EV 1P2 1P5 101 2P2 2P5 201 N4 install TM1 TM2 ...
Страница 86: ...Chapter 6 Peripherals 6 4 z JNFS21015 22 07 FOR EV 202 203 H1 z JNFS21016 15 07 FOR EV 202 203 H3 ...
Страница 87: ...Chapter 6 Peripherals 6 5 z JNFS20858 7 07 FOR EV 401 403 H3 ...