Chapter 3 Environment description and installation
3-15
Over load protection Inverter rated current 150%/1min
International
conformity
UL/CE
Over voltage
200V Class: DC voltage >400V 400V Class: DC voltage >800V
Under voltage
200V Class: DC voltage <190V 400 Class: DC voltage <380V
Instantaneous power
loss restart
Set to enable or disable
Stall prevention
ACC/DEC/ Operation stall prevention and stall prevention level.
Output terminal
short circuit
Electronic circuit protection
Other fault
Electronic circuit protection
Protective F
unctions
Other function
Over current, over voltage, under voltage, over load, instantaneous power loss
restart, ACC/DEC/ Operation stall prevention, output terminal sort circuit,
grounding error, reverse limit, directly start as power on and fault reset limit.
※
Note1: The setting resolution of above 100 Hz is 1Hz when controlled with operation
keypad, and 0.01 Hz when controlled using computer(PC) or programmable
controller(PLC).
Not
※
e2: EV-1P2~101-H1
;
2P2~201-H1/H3
,
401~403-H3 type (Fc=10KHz) with option filter can
accordance with EN61800-3 first environment restricted distribution.
EV-202~203-H1/H3 type (Fc=10KHz) with option filter can accordance with EN61800-3
first environment unrestricted distribution.
EV-2P2~201-H1F type (Fc=10KHz) & EV-202~203-H1F type (Fc=6KHz) with Build in
filter can accordance with EN61800-3 first environment unrestricted distribution.
(IP65) EV-2P2~403-H1(3)FN4(S) series & EV-401~403-H3F type (Fc=10KHz) with
Build in filter can accordance with EN61800-3 first environment restricted distribution.
Содержание 7300EV
Страница 14: ...Chapter 3 Environment description and installation 3 4 z EV 1P2 1P5 101 2P2 2P5 201 N4S install TM1 TM2 ...
Страница 15: ...Chapter 3 Environment description and installation 3 5 z EV 1P2 1P5 101 2P2 2P5 201 N4 install TM1 TM2 ...
Страница 86: ...Chapter 6 Peripherals 6 4 z JNFS21015 22 07 FOR EV 202 203 H1 z JNFS21016 15 07 FOR EV 202 203 H3 ...
Страница 87: ...Chapter 6 Peripherals 6 5 z JNFS20858 7 07 FOR EV 401 403 H3 ...