Chapter 4 Software index
4-13
F11~15
Selectable Functions for input trerminals ( S1-S4& AIN )
000: Forward Run
001: Reverse Run
002: Preset Speed Command 1
003: Preset Speed Command 2
004: Preset Speed Command 3
005: Jog frequency Command
006: Emergency stop(E.S.)
007: Base Block (b.b.)
008: Switching to 2nd acceleration/ deceleration time
009: Reset
010: Up command
011: Down command
012: Control signal switch
013: Communication mode. Disable – Enable.
014: Acceleration/deceleration prohibit
015: Master/Auxiliary speed switch
016: PID function prohibit
017: Analog frequency signal input ( terminal AIN)
0
018: PID feedback signal (terminal AIN)
1.) S1-AIN on TM2 are multi-function input terminals which can be set above 19 functions.
2.) F11~F15 function description:
F11~F15=000/001(Forward/ Reverse)
Forward command ON means inverter running forward, While OFF, the inverter stops. F11
factory default is forward command.
Reverse command ON means inverter running reverse, While OFF, the inverter stops. F12 factory
default is reverse command.
I f f o r wa r d – r ev e r se c o mma n d a r e O N a t t h e s a me t i me i t i s con s i d e r ed a s S t o p .
F11~F15=002~004(Preset Speed Command 1~3)
When run signal is applied and the selected external multi-function input terminal is on, the
inverter will run at one of 8 preset speeds which are controlled by the status of the terminals. The
corresponding speeds are as that programmed in parameters F28 to F36 as shown in the table
below.
F11~F15=005(Jog Frequency Command)
When run signal is applied and the selected external multi-function input terminal is on and set to
Jog speed, the inverter will run according to F36.
Priority of the frequency: Jog > preset speed
Preset Speed
Command 3
Set value=004
Preset Speed
Command 2
Set value=003
Preset Speed
Command 1
Set value=002
Jog Frequency
Command
Set value=005
Output
frequency
set value
X X X 1 F36
0 0 0 0
F28
0 0 1 0
F29
0 1 0 0
F30
0 1 1 0
F31
1 0 0 0
F32
1 0 1 0
F33
1 1 0 0
F34
1 1 1 0
F35
Содержание 7300EV
Страница 14: ...Chapter 3 Environment description and installation 3 4 z EV 1P2 1P5 101 2P2 2P5 201 N4S install TM1 TM2 ...
Страница 15: ...Chapter 3 Environment description and installation 3 5 z EV 1P2 1P5 101 2P2 2P5 201 N4 install TM1 TM2 ...
Страница 86: ...Chapter 6 Peripherals 6 4 z JNFS21015 22 07 FOR EV 202 203 H1 z JNFS21016 15 07 FOR EV 202 203 H3 ...
Страница 87: ...Chapter 6 Peripherals 6 5 z JNFS20858 7 07 FOR EV 401 403 H3 ...